ARC Chillers and refrigeration
NAICS 3+ Digits Required
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
UU0303 #01 Y:2026 Minimize condenser cooling water temperature $8,440 $18,000
NT0070 #04 Y:2026 Chill water to the highest temperature possible $6,625 -
MZ0399 #02 Y:2026 Chill water to the highest temperature possible $11,556 $7,906
MZ0399 #01 Y:2026 Replace existing chiller with high efficiency model $20,127 $127,250
IC0350 #05 Y:2026 Chill water to the highest temperature possible $3,509 -
IC0349 #07 Y:2026 Chill water to the highest temperature possible $1,452 $7,500
SU0599 #08 Y:2026 Chill water to the highest temperature possible $79 $143
CI0087 #03 Y:2026 Replace existing chiller with high efficiency model $56,064 $81,000
LE0615 #08 Y:2026 Replace existing chiller with high efficiency model $8,794 $22,000
LT8448 #01 Y:2026 Modify refrigeration system to operate at a lower pressure $59,448 $219,165
LE0612 #04 Y:2026 Replace existing chiller with high efficiency model $356,317 $250,000
MZ0397 #05 Y:2026 Replace existing chiller with high efficiency model $88,780 $279,688
UF0649 #06 Y:2026 Minimize condenser cooling water temperature $2,060 $1,508
LS0626 #02 Y:2026 Chill water to the highest temperature possible $10,589 $500
LS0526 #05 Y:2026 Replace existing chiller with high efficiency model $31,399 $70,000
LS0526 #02 Y:2026 Chill water to the highest temperature possible $27,684 $500
MZ0395 #02 Y:2026 Chill water to the highest temperature possible $25,270 -
SD0687 #01 Y:2026 Replace existing chiller with high efficiency model $3,112 $3,000
MS0470 #07 Y:2026 Chill water to the highest temperature possible $126 -
UU0301 #01 Y:2026 Chill water to the highest temperature possible $87,700 $282,000