Assessment Year | 2025 |
---|---|
Principal Product | Elementary School |
NAICS | 611110: Elementary and Secondary Schools |
SIC | 8211: Elementary and Secondary Schools |
Sales Range | less than $500 k |
# of Employees | 35 |
Plant Area |
92,025
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $120,392 | 1,531,000 |
kWh
|
$0.079 |
Electricity Demand | $14,548 | 3,531 |
kW-mo/yr
|
$4.12 |
TOTAL YEARLY COSTS | $134,940 | |||
RECOMMENDED SAVINGS* | $33,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2625: Chill water to the highest temperature possible | $8,927 | $500 |
$8,927
112,997
kWh
|
- | |
02 | 2.7423: Reduce heat gain by window tinting | $11,016 | $2,940 |
$11,016
139,443
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,793 | $5,074 |
$5,475
69,306
kWh
|
$1,318
-
kW-mo/yr
|
|
04 | 2.7425: Clean or color roof to reduce solar load | $6,367 | $24,944 |
$6,367
80,595
kWh
|
- | |
TOTAL RECOMMENDED | $33,103 | $33,458 |
$31,785
402,341
kWh
|
$1,318
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs