ITAC Center of the Year: 2022
The University of Missouri-Columbia Industrial Assessment Center (MZ-ITAC) provides free energy, productivity, and waste assessments to small and medium-sized industrial facilities through funding provided by the US Department of Energy.
342 | Assessments |
2,311 | Recommendations |
4.45 | Tbtu Energy Saving* |
$44.89 | million Cost Savings* |
241 | Students Trained |
*Recommended Savings
University of Missouri-Columbia also coordinates activities with:
Wichita State University
Energy Engineering related programs, degrees, etc:
Related Papers & Publications
Wu, B., Education the next generation of energy-savvy workforce, American Journal of Engineering Education, Vol. 4, pp85-91, 2013
Wu, B. and J. Abad, Model of Collaboration to Promote Energy Efficiency, 2013 Int. Academic Conf., Paris, Paris, 2013
Wu, B., Sandina Ponte and A. Khoshkhoo, Computer-Aided Adaptation of Superior Energy Performance and ISO50001, 2013 International Academic Conference, Paris, 2013
Noteworthy Feedback
"I wanted to take the opportunity to provide you direct comment regarding the University of Missouri – Midwest Industrial Assessment Center (MIAC) and the... more"
- Source: Glen Lewis, Senior Program Manager, 2023-08-12
"Overall, the IAC Team from UMOC was very useful to us. In addition to the line items identified, having the IAC report gave us a platform to discuss our... more"
- Source: Ross Tompkins, Sealed Air, 2024-04-25
"IAC and the DOE have been critical to help ensure the continued success of local manufacturing by ensuring continued improvement for facilities and utility... more"
- Source: Grahm Meyer, AZZ Swichgear Systems, 2023-06-08
Papers & Publications
2013
6 Papers / Publications
Bin Wu, Sandina Ponte, and Chatchai Pinthuprapa, Institutionalization of Industrial Best Practice of Energy Efficiency: The Case of a Global Manufacturing Organization, Periodical of Applied Mechanics and Materials Vols. 316-317 (2013) pp 91-94, Trans Tech Publications, Switzerland | University of Missouri-Columbia ITAC
Wu, B., Education the next generation of energy-savvy workforce, American Journal of Engineering Education, Vol. 4, pp85-91 | University of Missouri-Columbia ITAC
Wu, B., The Complete Cycle to Achieve Industrial Energy Efficiency – Concept, Resources, And Application, Journal of International Energy Policy – Spring 2013 Volume 2, Number 1, pp 23-30 | University of Missouri-Columbia ITAC
Bin Wu, Sandina Ponte and Chatchai Pinthuprapa, Institutionalization of Industrial Best Practice of Energy Efficiency: The Case of a Global Manufacturing Organization, Proceedings of International Conference of Energy and Environmental Engineering (ICEEEE 2013), E253 | University of Missouri-Columbia ITAC
Wu, B., Sandina Ponte and A. Khoshkhoo, Computer-Aided Adaptation of Superior Energy Performance and ISO50001, 2013 International Academic Conference, Paris | University of Missouri-Columbia ITAC
Wu, B. and J. Abad, Model of Collaboration to Promote Energy Efficiency, 2013 Int. Academic Conf., Paris, Paris | University of Missouri-Columbia ITAC
2012
5 Papers / Publications
Wu, B., Sandina Ponte, Institutionalizing Energy Efficiency within the Manufacturing Industry: a Computer-Aided Framework for ISO50001, Proceedings of 2nd International Conference on Environment and Industrial Innovation (ICEII2012), Hong Kong | University of Missouri-Columbia ITAC
Wu, B., The Complete Cycle to Achieve Industrial Energy Efficiency – Concept, Resources, and Application, Proceedings of International Academic Conference, Maui | University of Missouri-Columbia ITAC
Wu, B., Educating the Next Generation of Energy-Savvy Workforce, Proceeding of International Academic Conference, RHI13-348, Maui | University of Missouri-Columbia ITAC
Wu, B., J. Wibbenmeyer, A. Khoshkhoo, Setting Achievable Goals for Industrial Energy Efficiency – a Structured Approach, Proceedings of International Academic Conference, Maui | University of Missouri-Columbia ITAC
C. Pinthuprapa, B. Wu, A Study of the Effectiveness of Energy Services in Public Schools, Proceedings of International Academic Conference, Maui | University of Missouri-Columbia ITAC
2011
1 Papers / Publications
Wu, B, The Complete Cycle to Institutionalize Energy Efficiency – Conceptual Framework, Tools, and Industrial Cases, Proceeding of Annual Conference of ACEEE, June, Niagara Falls | University of Missouri-Columbia ITAC
2009
3 Papers / Publications
Wu, B, A State-Wide Effort to Promote Best Practices in Industrial Energy Efficiency in Missouri, Proceedings of 2009 Energy Summit, pp243-251, ACEEE, White Water, NY | University of Missouri-Columbia ITAC
Wu, B, et al, Manual Process Productivity Measurement — A Case Study in Pre-registration Department, SHS Annual Conference, Chicago | University of Missouri-Columbia ITAC
Wu, B, How to improve energy efficiency in the manufacturing sector, Annual MUPA conference | University of Missouri-Columbia ITAC
2008
3 Papers / Publications
Khanna S., Wu, B., A Multi-Pronged Approach to Achieving Energy Efficiency, Annual Conference of American Society of Mechanical Engineers (ASME), Washington | University of Missouri-Columbia ITAC
Wu, B., Story, J., Tara O'Hare, Win, Win, Win: Integrating Lean, Clean and Energy Assessments, MEP National Conference, Orlando | University of Missouri-Columbia ITAC
Wu, B, Identification of opportunities for improvement of industrial energy efficiency, Midwest Energy Summit, Columbia, USA | University of Missouri-Columbia ITAC
2007
3 Papers / Publications
Wu, B., A Systematic Effort to Promote Best Practices in Industrial Energy Efficiency, Annual Conference of ACEEE, Washington DC | University of Missouri-Columbia ITAC
Wu, B., Conceptual Framework of Healthcare Systems Engineering and Pilot Curriculum Development, Annual Conf of American Society for Engineering Education, Hawaii | University of Missouri-Columbia ITAC
Wu, B., Promoting Awareness of Industrial Energy Efficiency and Waste Reduction in the University Students Population, Annual Conf of American Society for Engineering Education, Hawaii | University of Missouri-Columbia ITAC
Noteworthy Feedback
"Jan. 7, 2020: Working with Sanjeev and his students was nothing short of professional and educating. From the first interaction with the students you could tell that there was real interest in the work that they were doing. The areas that they indicated improvements and the estimated cost savings made it really easy to justify the costs of the upgrades. I would highly recommend this group to any company or cooperation looking to modernize and become more efficient with the energy they consume.
March 29, 2019: I have printed and briefly went through the review. This is a great amount of work and am excited to thoroughly read through this and look at how we can save money on electrical consumption as well as water. I will provide some feedback/comments after I go through it completely.
Thank you very much again for the diligent work you and the students have put into this I greatly appreciate it.
Best Regards,
Joshua B. Youngblood
Asst. Water Quality Superintendent-Wastewater"
"Jan. 7, 2020: Working with Sanjeev and his students was nothing short of professional and educating. From the first interaction with the students you could tell that there was real interest in the work that they were doing. The areas that they indicated improvements and the estimated cost savings made it really easy to justify the costs of the upgrades. I would highly recommend this group to any company or cooperation looking to modernize and become more efficient with the energy they consume.
March 29, 2019: I have printed and briefly went through the review. This is a great amount of work and am excited to thoroughly read through this and look at how we can save money on electrical consumption as well as water. I will provide some feedback/comments after I go through it completely.
Thank you very much again for the diligent work you and the students have put into this I greatly appreciate it.
Best Regards,
Joshua B. Youngblood
Asst. Water Quality Superintendent-Wastewater"
"Jan. 7, 2020: Working with Sanjeev and his students was nothing short of professional and educating. From the first interaction with the students you could tell that there was real interest in the work that they were doing. The areas that they indicated improvements and the estimated cost savings made it really easy to justify the costs of the upgrades. I would highly recommend this group to any company or cooperation looking to modernize and become more efficient with the energy they consume.
March 29, 2019: I have printed and briefly went through the review. This is a great amount of work and am excited to thoroughly read through this and look at how we can save money on electrical consumption as well as water. I will provide some feedback/comments after I go through it completely.
Thank you very much again for the diligent work you and the students have put into this I greatly appreciate it.
Best Regards,
Joshua B. Youngblood
Asst. Water Quality Superintendent-Wastewater"
"Jan. 7, 2020: Working with Sanjeev and his students was nothing short of professional and educating. From the first interaction with the students you could tell that there was real interest in the work that they were doing. The areas that they indicated improvements and the estimated cost savings made it really easy to justify the costs of the upgrades. I would highly recommend this group to any company or cooperation looking to modernize and become more efficient with the energy they consume.
March 29, 2019: I have printed and briefly went through the review. This is a great amount of work and am excited to thoroughly read through this and look at how we can save money on electrical consumption as well as water. I will provide some feedback/comments after I go through it completely.
Thank you very much again for the diligent work you and the students have put into this I greatly appreciate it.
Best Regards,
Joshua B. Youngblood
Asst. Water Quality Superintendent-Wastewater"
- Source: Joshua Youngblood, Assistant Water Quality Superintendent, 2020-01-07
"Thank you , this is great work."
- Source: Jeffery Ostermann, Director - Operations, 2019-08-19
"Bhuvnesh wrote: Thank you, Dr. Khanna, it was a pleasure for our Mascoutah team to learn the techniques of energy assessment from you.
Amy wrote: Thank you and your team for the onsite assessment and providing the detailed report; I have filed the report and intend to visit each recommendation and request action to implementation opportunity. I thoroughly enjoyed having your students and the length of detail to supply Legrand Cablofil with sustainability projects that identifies the cost savings and energy reduction efforts maximum impact. Legrand Cablofil is committed to setting objectives intended to improve our environmental performance by taking action to protect the environment, meeting compliance obligation and continually improving. Thank you for your support in those efforts and reaching our sustainability and energy reduction goals."
"Bhuvnesh wrote: Thank you, Dr. Khanna, it was a pleasure for our Mascoutah team to learn the techniques of energy assessment from you.
Amy wrote: Thank you and your team for the onsite assessment and providing the detailed report; I have filed the report and intend to visit each recommendation and request action to implementation opportunity. I thoroughly enjoyed having your students and the length of detail to supply Legrand Cablofil with sustainability projects that identifies the cost savings and energy reduction efforts maximum impact. Legrand Cablofil is committed to setting objectives intended to improve our environmental performance by taking action to protect the environment, meeting compliance obligation and continually improving. Thank you for your support in those efforts and reaching our sustainability and energy reduction goals."
"Bhuvnesh wrote: Thank you, Dr. Khanna, it was a pleasure for our Mascoutah team to learn the techniques of energy assessment from you.
Amy wrote: Thank you and your team for the onsite assessment and providing the detailed report; I have filed the report and intend to visit each recommendation and request action to implementation opportunity. I thoroughly enjoyed having your students and the length of detail to supply Legrand Cablofil with sustainability projects that identifies the cost savings and energy reduction efforts maximum impact. Legrand Cablofil is committed to setting objectives intended to improve our environmental performance by taking action to protect the environment, meeting compliance obligation and continually improving. Thank you for your support in those efforts and reaching our sustainability and energy reduction goals."
"Bhuvnesh wrote: Thank you, Dr. Khanna, it was a pleasure for our Mascoutah team to learn the techniques of energy assessment from you.
Amy wrote: Thank you and your team for the onsite assessment and providing the detailed report; I have filed the report and intend to visit each recommendation and request action to implementation opportunity. I thoroughly enjoyed having your students and the length of detail to supply Legrand Cablofil with sustainability projects that identifies the cost savings and energy reduction efforts maximum impact. Legrand Cablofil is committed to setting objectives intended to improve our environmental performance by taking action to protect the environment, meeting compliance obligation and continually improving. Thank you for your support in those efforts and reaching our sustainability and energy reduction goals."
- Source: Bhuvnesh Joshi, Amy LeMay, Energy Engineer, Environmental Health Safety Manager, Legrand, 2018-01-03
"Such a wonderful opportunity - you can use me as a reference anytime!"
"Dr. Wu,
Thank you for the follow up to the audit you and the students performed last year. I found the observations very insightful and relevant to our manufacturing operation. It was extremely helpful to learn how to quantify the savings. It is easy to overlook and avoid making the investments until you place a value on what it costs you in energy costs. Though we are unable to implement some of the items we've taken the first steps with trading out the light fixtures throughout the facility as suggested by your audit team.
Best regards,
Drew Dubray
General Manger
Koken Manufacturing"
"Such a wonderful opportunity - you can use me as a reference anytime!"
"Dr. Wu,
Thank you for the follow up to the audit you and the students performed last year. I found the observations very insightful and relevant to our manufacturing operation. It was extremely helpful to learn how to quantify the savings. It is easy to overlook and avoid making the investments until you place a value on what it costs you in energy costs. Though we are unable to implement some of the items we've taken the first steps with trading out the light fixtures throughout the facility as suggested by your audit team.
Best regards,
Drew Dubray
General Manger
Koken Manufacturing"
"Such a wonderful opportunity - you can use me as a reference anytime!"
"Dr. Wu,
Thank you for the follow up to the audit you and the students performed last year. I found the observations very insightful and relevant to our manufacturing operation. It was extremely helpful to learn how to quantify the savings. It is easy to overlook and avoid making the investments until you place a value on what it costs you in energy costs. Though we are unable to implement some of the items we've taken the first steps with trading out the light fixtures throughout the facility as suggested by your audit team.
Best regards,
Drew Dubray
General Manger
Koken Manufacturing"
"Such a wonderful opportunity - you can use me as a reference anytime!"
"Dr. Wu,
Thank you for the follow up to the audit you and the students performed last year. I found the observations very insightful and relevant to our manufacturing operation. It was extremely helpful to learn how to quantify the savings. It is easy to overlook and avoid making the investments until you place a value on what it costs you in energy costs. Though we are unable to implement some of the items we've taken the first steps with trading out the light fixtures throughout the facility as suggested by your audit team.
Best regards,
Drew Dubray
General Manger
Koken Manufacturing"
- Source: Drew Dubray, Plant Manager, Takara Belmont, 2017-03-29
" ... thank you for taking the time to follow up. There was a lot of good information in the report that I have budgeted in 2011 to correct.
Thanks again,"
- Source: Tim Wagner, Plant Operations Manager, Cott Beverages, 2015-10-15
"Hi Dr. Wu,
Thank you for putting this together. We appreciate the time you and your team spent on this. We will review and get back to you with any questions and I will see if I can involve any other sites.
Thanks again,"
Also feedback from one of the MoIAC student team member (Jeff Hoiday):
"... I first want to thank you for introducing me into the world of energy efficiency and sustainable energy. The opportunity that you (IAC) provided was one that would change my outlook on the ever bearing question of what I want to do when I graduate. You opened the door for me to finally answer that question."
"Hi Dr. Wu,
Thank you for putting this together. We appreciate the time you and your team spent on this. We will review and get back to you with any questions and I will see if I can involve any other sites.
Thanks again,"
Also feedback from one of the MoIAC student team member (Jeff Hoiday):
"... I first want to thank you for introducing me into the world of energy efficiency and sustainable energy. The opportunity that you (IAC) provided was one that would change my outlook on the ever bearing question of what I want to do when I graduate. You opened the door for me to finally answer that question."
"Hi Dr. Wu,
Thank you for putting this together. We appreciate the time you and your team spent on this. We will review and get back to you with any questions and I will see if I can involve any other sites.
Thanks again,"
Also feedback from one of the MoIAC student team member (Jeff Hoiday):
"... I first want to thank you for introducing me into the world of energy efficiency and sustainable energy. The opportunity that you (IAC) provided was one that would change my outlook on the ever bearing question of what I want to do when I graduate. You opened the door for me to finally answer that question."
"Hi Dr. Wu,
Thank you for putting this together. We appreciate the time you and your team spent on this. We will review and get back to you with any questions and I will see if I can involve any other sites.
Thanks again,"
Also feedback from one of the MoIAC student team member (Jeff Hoiday):
"... I first want to thank you for introducing me into the world of energy efficiency and sustainable energy. The opportunity that you (IAC) provided was one that would change my outlook on the ever bearing question of what I want to do when I graduate. You opened the door for me to finally answer that question."
- Source: Thomas Wagner, Production Manager, Nestle Purina, 2015-06-25
""Hello Bin -
My Maintenance team upgraded the building BMS controls in 2014. In Oct 2014, we tested & Nov refined the control.
The results. In a same time comparison, the site used 814,229 kWh less Jan - May 2013 & 423,564 kWh less than Jan - May 2014.
We implemented 1-3. 4 & 5 were not done."
Update from the company's Sustainability Manager, On Dec 16 2015 Mr. Jeffery Whitford wrote: "I just wanted to reach out to let you know that we're in the very early stages of a major energy efficiency investment. Our business went through a major transition over the past few months as we were acquired by XXXX, Germany. There is an even greater focus on environmental sustainability and investment in energy efficiency. I expect that with this change we will be working on implementing the things you outlined in the coming year or two since we're looking a 3 year program that is probably in the range of a $5 - $15 M investment (coop - wide).
Thank you again ....jw"
"
""Hello Bin -
My Maintenance team upgraded the building BMS controls in 2014. In Oct 2014, we tested & Nov refined the control.
The results. In a same time comparison, the site used 814,229 kWh less Jan - May 2013 & 423,564 kWh less than Jan - May 2014.
We implemented 1-3. 4 & 5 were not done."
Update from the company's Sustainability Manager, On Dec 16 2015 Mr. Jeffery Whitford wrote: "I just wanted to reach out to let you know that we're in the very early stages of a major energy efficiency investment. Our business went through a major transition over the past few months as we were acquired by XXXX, Germany. There is an even greater focus on environmental sustainability and investment in energy efficiency. I expect that with this change we will be working on implementing the things you outlined in the coming year or two since we're looking a 3 year program that is probably in the range of a $5 - $15 M investment (coop - wide).
Thank you again ....jw"
"
""Hello Bin -
My Maintenance team upgraded the building BMS controls in 2014. In Oct 2014, we tested & Nov refined the control.
The results. In a same time comparison, the site used 814,229 kWh less Jan - May 2013 & 423,564 kWh less than Jan - May 2014.
We implemented 1-3. 4 & 5 were not done."
Update from the company's Sustainability Manager, On Dec 16 2015 Mr. Jeffery Whitford wrote: "I just wanted to reach out to let you know that we're in the very early stages of a major energy efficiency investment. Our business went through a major transition over the past few months as we were acquired by XXXX, Germany. There is an even greater focus on environmental sustainability and investment in energy efficiency. I expect that with this change we will be working on implementing the things you outlined in the coming year or two since we're looking a 3 year program that is probably in the range of a $5 - $15 M investment (coop - wide).
Thank you again ....jw"
"
""Hello Bin -
My Maintenance team upgraded the building BMS controls in 2014. In Oct 2014, we tested & Nov refined the control.
The results. In a same time comparison, the site used 814,229 kWh less Jan - May 2013 & 423,564 kWh less than Jan - May 2014.
We implemented 1-3. 4 & 5 were not done."
Update from the company's Sustainability Manager, On Dec 16 2015 Mr. Jeffery Whitford wrote: "I just wanted to reach out to let you know that we're in the very early stages of a major energy efficiency investment. Our business went through a major transition over the past few months as we were acquired by XXXX, Germany. There is an even greater focus on environmental sustainability and investment in energy efficiency. I expect that with this change we will be working on implementing the things you outlined in the coming year or two since we're looking a 3 year program that is probably in the range of a $5 - $15 M investment (coop - wide).
Thank you again ....jw"
"
- Source: Kurt McClellan, Jeffery Whitford, Environmental and Sustainability Manager, Sigma-Aldrich, 2015-06-08
"This audit has resulted approximately $400,000 annual saving through implementation of recommendations - very close to the estimation in as our report (company recorded 10% of savings out of $4.5M utility costs/year):
"Good Afternoon Dr. Wu,
... I will update you on your findings during your team’s energy audit at Piramal. It should also be noted that our plant has formed an “Energy Pillar Team†in an effort to achieve a level 3 status in our “Operational Excellence†program....
...
AR2. Our XXX furnace was repaired not long after your audit. This furnace is operating more efficiently. Our XXX Furnace is being scheduled for a repair in xxxx.
AR3. I have initiated a quoted project using Ameren’s rebate program. I currently have a proposal to install VFDs on all of our fans before our Corporate office awaiting approval.
AR4. At present our XXX is down for a rebuild and upgrade. I also have an approved project through Ameren’s rebate program to improve control of our compressors. This project includes leak detection and repair of our compressed air system. This project to be completed before November of this year.
AR5. This is a viable suggestion which has yet to be implemented.
AR6. This suggestion is part of the compressed air project mentioned above and will be implemented as funds become available.
AR7. As belts are changed in the course of PM’s, we are re-installing cogged V-belts. Estimate 50% of belts are now cogged.
AR8. Resetting of thermostats for the most part has been accomplished. Problem with keeping unauthorized personnel from changing settings will have to be addressed.
AR9. Photo-eyes have been installed and are working well.
· Preliminary data shows electrical saving of about 10% over previous year with just the implemented items.
· Our Energy Pillar Team is working to establish data collection with more detail.
· I will stay in touch as more data becomes available.
Sincerely,""
"This audit has resulted approximately $400,000 annual saving through implementation of recommendations - very close to the estimation in as our report (company recorded 10% of savings out of $4.5M utility costs/year):
"Good Afternoon Dr. Wu,
... I will update you on your findings during your team’s energy audit at Piramal. It should also be noted that our plant has formed an “Energy Pillar Team†in an effort to achieve a level 3 status in our “Operational Excellence†program....
...
AR2. Our XXX furnace was repaired not long after your audit. This furnace is operating more efficiently. Our XXX Furnace is being scheduled for a repair in xxxx.
AR3. I have initiated a quoted project using Ameren’s rebate program. I currently have a proposal to install VFDs on all of our fans before our Corporate office awaiting approval.
AR4. At present our XXX is down for a rebuild and upgrade. I also have an approved project through Ameren’s rebate program to improve control of our compressors. This project includes leak detection and repair of our compressed air system. This project to be completed before November of this year.
AR5. This is a viable suggestion which has yet to be implemented.
AR6. This suggestion is part of the compressed air project mentioned above and will be implemented as funds become available.
AR7. As belts are changed in the course of PM’s, we are re-installing cogged V-belts. Estimate 50% of belts are now cogged.
AR8. Resetting of thermostats for the most part has been accomplished. Problem with keeping unauthorized personnel from changing settings will have to be addressed.
AR9. Photo-eyes have been installed and are working well.
· Preliminary data shows electrical saving of about 10% over previous year with just the implemented items.
· Our Energy Pillar Team is working to establish data collection with more detail.
· I will stay in touch as more data becomes available.
Sincerely,""
"This audit has resulted approximately $400,000 annual saving through implementation of recommendations - very close to the estimation in as our report (company recorded 10% of savings out of $4.5M utility costs/year):
"Good Afternoon Dr. Wu,
... I will update you on your findings during your team’s energy audit at Piramal. It should also be noted that our plant has formed an “Energy Pillar Team†in an effort to achieve a level 3 status in our “Operational Excellence†program....
...
AR2. Our XXX furnace was repaired not long after your audit. This furnace is operating more efficiently. Our XXX Furnace is being scheduled for a repair in xxxx.
AR3. I have initiated a quoted project using Ameren’s rebate program. I currently have a proposal to install VFDs on all of our fans before our Corporate office awaiting approval.
AR4. At present our XXX is down for a rebuild and upgrade. I also have an approved project through Ameren’s rebate program to improve control of our compressors. This project includes leak detection and repair of our compressed air system. This project to be completed before November of this year.
AR5. This is a viable suggestion which has yet to be implemented.
AR6. This suggestion is part of the compressed air project mentioned above and will be implemented as funds become available.
AR7. As belts are changed in the course of PM’s, we are re-installing cogged V-belts. Estimate 50% of belts are now cogged.
AR8. Resetting of thermostats for the most part has been accomplished. Problem with keeping unauthorized personnel from changing settings will have to be addressed.
AR9. Photo-eyes have been installed and are working well.
· Preliminary data shows electrical saving of about 10% over previous year with just the implemented items.
· Our Energy Pillar Team is working to establish data collection with more detail.
· I will stay in touch as more data becomes available.
Sincerely,""
"This audit has resulted approximately $400,000 annual saving through implementation of recommendations - very close to the estimation in as our report (company recorded 10% of savings out of $4.5M utility costs/year):
"Good Afternoon Dr. Wu,
... I will update you on your findings during your team’s energy audit at Piramal. It should also be noted that our plant has formed an “Energy Pillar Team†in an effort to achieve a level 3 status in our “Operational Excellence†program....
...
AR2. Our XXX furnace was repaired not long after your audit. This furnace is operating more efficiently. Our XXX Furnace is being scheduled for a repair in xxxx.
AR3. I have initiated a quoted project using Ameren’s rebate program. I currently have a proposal to install VFDs on all of our fans before our Corporate office awaiting approval.
AR4. At present our XXX is down for a rebuild and upgrade. I also have an approved project through Ameren’s rebate program to improve control of our compressors. This project includes leak detection and repair of our compressed air system. This project to be completed before November of this year.
AR5. This is a viable suggestion which has yet to be implemented.
AR6. This suggestion is part of the compressed air project mentioned above and will be implemented as funds become available.
AR7. As belts are changed in the course of PM’s, we are re-installing cogged V-belts. Estimate 50% of belts are now cogged.
AR8. Resetting of thermostats for the most part has been accomplished. Problem with keeping unauthorized personnel from changing settings will have to be addressed.
AR9. Photo-eyes have been installed and are working well.
· Preliminary data shows electrical saving of about 10% over previous year with just the implemented items.
· Our Energy Pillar Team is working to establish data collection with more detail.
· I will stay in touch as more data becomes available.
Sincerely,""
- Source: Dan Hoover, Plant Engineer, Piramal Glass, 2015-06-08
"On Jul 30, 2013, at 4:12 PM, Joe Kaufman <JKaufman@ofalloncasting.com> wrote:
Dr. Bin Wu
O'Fallon Casting would like to thank Dr. Bin Wu and the IAC team for the Assessment report that helped us to review the recommendations for Compressed Air, Broken Seals on Oven Doors, Insulating all of our steam pipes, heat recovery and replacing our old 1978 Boiler with a new efficient Boiler. These completed recommendations will result in actual cost savings, reduction in CO2 emissions, a reduction in electric and natural gas consumption. You and your team are always welcome at O'Fallon Casting.
Thanks
Joseph J.Kaufman
Human Resource & Environmental Mgr.
"
"On Jul 30, 2013, at 4:12 PM, Joe Kaufman <JKaufman@ofalloncasting.com> wrote:
Dr. Bin Wu
O'Fallon Casting would like to thank Dr. Bin Wu and the IAC team for the Assessment report that helped us to review the recommendations for Compressed Air, Broken Seals on Oven Doors, Insulating all of our steam pipes, heat recovery and replacing our old 1978 Boiler with a new efficient Boiler. These completed recommendations will result in actual cost savings, reduction in CO2 emissions, a reduction in electric and natural gas consumption. You and your team are always welcome at O'Fallon Casting.
Thanks
Joseph J.Kaufman
Human Resource & Environmental Mgr.
"
"On Jul 30, 2013, at 4:12 PM, Joe Kaufman <JKaufman@ofalloncasting.com> wrote:
Dr. Bin Wu
O'Fallon Casting would like to thank Dr. Bin Wu and the IAC team for the Assessment report that helped us to review the recommendations for Compressed Air, Broken Seals on Oven Doors, Insulating all of our steam pipes, heat recovery and replacing our old 1978 Boiler with a new efficient Boiler. These completed recommendations will result in actual cost savings, reduction in CO2 emissions, a reduction in electric and natural gas consumption. You and your team are always welcome at O'Fallon Casting.
Thanks
Joseph J.Kaufman
Human Resource & Environmental Mgr.
"
"On Jul 30, 2013, at 4:12 PM, Joe Kaufman <JKaufman@ofalloncasting.com> wrote:
Dr. Bin Wu
O'Fallon Casting would like to thank Dr. Bin Wu and the IAC team for the Assessment report that helped us to review the recommendations for Compressed Air, Broken Seals on Oven Doors, Insulating all of our steam pipes, heat recovery and replacing our old 1978 Boiler with a new efficient Boiler. These completed recommendations will result in actual cost savings, reduction in CO2 emissions, a reduction in electric and natural gas consumption. You and your team are always welcome at O'Fallon Casting.
Thanks
Joseph J.Kaufman
Human Resource & Environmental Mgr.
"
- Source: Joe Kaufman, HR & Environmental Manager, O, 2013-07-30
"Dr. Wu,
It was truly a pleasure to speak with you again. Please find the attached document which demonstrates we have reduced our KWH consumption by 13.9% (while producing more product) since your visit. Thanks again for your assistance and don’t hesitate to call if you need any additional data.
Jason C. Hamblen
Ring Container Technologies
Saint Joseph, MO"
"Dr. Wu,
It was truly a pleasure to speak with you again. Please find the attached document which demonstrates we have reduced our KWH consumption by 13.9% (while producing more product) since your visit. Thanks again for your assistance and don’t hesitate to call if you need any additional data.
Jason C. Hamblen
Ring Container Technologies
Saint Joseph, MO"
"Dr. Wu,
It was truly a pleasure to speak with you again. Please find the attached document which demonstrates we have reduced our KWH consumption by 13.9% (while producing more product) since your visit. Thanks again for your assistance and don’t hesitate to call if you need any additional data.
Jason C. Hamblen
Ring Container Technologies
Saint Joseph, MO"
"Dr. Wu,
It was truly a pleasure to speak with you again. Please find the attached document which demonstrates we have reduced our KWH consumption by 13.9% (while producing more product) since your visit. Thanks again for your assistance and don’t hesitate to call if you need any additional data.
Jason C. Hamblen
Ring Container Technologies
Saint Joseph, MO"
- Source: Jason C. Hamblen, Plant Manager, Ring Container Technologies, 2011-07-20
Contact Center
Center Director | Sanjeev Khanna |
khannas@missouri.edu | |
Phone # | 1 (573) 884-9109 |
Mailing Address |
E3412, Thomas and Nell Lafferre Hall, Mechanical & Aerospace Engineering Department University of Missouri Columbia, MO 65211 |
Assistant Director | Deepak Gupta |
Assistant Director | Yue Jin |
University of Missouri-Columbia has trained 241 students
The following students participated in ITAC assessments with University of Missouri-Columbia since
2007.
The 85 students (in BOLD) have also been awarded ITAC student certificates for exceptional participation.
The 85 students (in BOLD) have also been awarded ITAC student certificates for exceptional participation.
Abdul Syed |
Abdun Khalid |
Adam Blumhagen |
Adam Byrnes |
Adam Dkhili |
Adam Reddy |
Adithyan Babu |
Ahad Hosseini |
Ahmed Bagaber |
Ahmed Boucherih |
Akhouri Amitanand Sinha |
Alex Cunningham |
Alex Straughn |
Alexsander Crowe |
Ali Anvari |
Ali I. Alhajji |
Ali Khoshkhoo |
Alvin Lemaiyan |
Ananth Chandrasekaran |
Andrew Labarge |
Andrew Polizzi |
Andrew Pollizi |
Andrew Reinhard |
Andrew Townsend |
Anirban Sarkar |
Anthony Iannicola |
Anurag Bommara |
Anurathi Rajavally |
Aravind Sri Saravanan Sevvilam Parithi |
Arockia Stephna Maria Das Anna Victor |
Ashley May |
Asif R. Raz |
Audrey Wood |
Austin Laramie |
Avery Decker |
Babu Adithyan |
Bahram Rajabi Far |
Behnam Sabzi |
BeiJia Yao |
Ben J Simon |
Ben Weiselman |
Benjamin Beer |
Benjamin King |
Bibish Chaulagain |
Bichen Zhang |
Bilal Hameed |
Blake Price |
Bradford Barnett |
Brady Beckham |
Brandon Beck |
Brian Kenney |
Brianne Mcnutt |
Brohde Bennett |
Candice Dussold |
Caroline C. Langley |
Caroline Junker |
Celeste Blum |
Chatchai Pinthuprapa |
Chathura Wickreme Seneviratne |
Chi Yang |
Chitralekha Chakraborty |
Christian A. Hoyos Broja |
Christine Anjali Noel Ramesh |
Christopher Wurzer |
Cole Harms |
Colin McCarthy |
Colm Barry |
Connor mcMillin |
Connor Reed Walter |
Curtis Singer |
Daniel mcGarth |
David Nunez |
Dawei Li |
Desiree Smith |
Devi Vara Prasad Rayapaneni |
Dian Trihastuti |
Diarmait Ryan-Anderson |
Divya Teja Pinnamaneni |
Dong Yi |
Dustin Smith |
Dylan Eades |
Edgar Olet |
Eric Obermark |
Evan King |
Fengmin Su |
Gabriel Ingram |
Gargi Dashora |
Gaurav Sangamnerkar |
Gerhard Scheiders |
Giridhar Pemmireddi |
Graham French |
Graham Walter |
Gregory Allers |
Gunjan Indapurkar |
Haijun Li |
Harrision CLark |
Harrison Clark |
Harsimranjot Singh Grewal |
Hemant Tiwari |
Huali Sun |