| Assessment Year | 2025 |
|---|---|
| Principal Product | Vitamins and nutritional products |
| NAICS | 311999: All Other Miscellaneous Food Manufacturing |
| SIC | 2076: Vegetable Oil Mills, Except Corn, Cottonseed, and Soybean |
| Sales Range | $50 M to 100M |
| # of Employees | 55 |
| Plant Area |
53,000
ft2
|
| Annual Production | 111,820
lb
|
| Production Hrs. Annual | 3,060
hrs
|
| Location (State) | Maryland |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $362,175 | 3,963,042 |
kWh
|
$0.091 | |
| Electricity Demand | $46,295 | 8,589 |
kW-mo/yr
|
$5.39 | |
| Electricity Fees | $133,261 | - |
|
- | |
| Waste Disposal Costs | |||||
| Water Usage | $17,477 | 5,454 |
Tgal
|
$3.20 | |
| Water Disposal | $25,882 | 5,454 |
Tgal
|
$4.75 | |
| TOTAL YEARLY COSTS | $585,090 | ||||
| RECOMMENDED SAVINGS* | $56,264 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $35,325 | $5,420 |
$28,690
313,900
kWh
|
$6,635
-
kW-mo/yr
|
- | |
| 02 | 2.7226: Use computer programs to optimize hvac performance | $5,930 | $12,005 |
$4,814
52,670
kWh
|
$1,116
-
kW-mo/yr
|
- | |
| 03 | 2.4224: Upgrade controls on compressors | $3,312 | $5,557 |
$2,999
32,673
kWh
|
$313
-
kW-mo/yr
|
- | |
| 04 | 2.7245: Use direct air supply to exhaust hoods | $2,894 | $6,400 |
$2,350
25,711
kWh
|
$544
-
kW-mo/yr
|
- | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,760 | $7,928 |
$2,555
27,949
kWh
|
$205
-
kW-mo/yr
|
- | |
| 06 | 2.1336: Install equipment to utilize waste fuel | $2,729 | $3,800 |
$2,217
24,251
kWh
|
$512
-
kW-mo/yr
|
- | |
| 07 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $1,711 | $5,800 |
$1,313
14,362
kWh
|
$302
-
kW-mo/yr
|
$96 | |
| 08 | 2.2625: Chill water to the highest temperature possible | $866 | $1,550 |
$704
7,705
kWh
|
$162
-
kW-mo/yr
|
- | |
| 09 | 2.7135: Install occupancy sensors | $458 | $1,800 |
$361
3,932
kWh
|
$97
-
kW-mo/yr
|
- | |
| 10 | 2.2511: Insulate bare equipment | $279 | $153 |
$225
2,462
kWh
|
$54
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $56,264 | $50,413 |
$46,228
505,615
kWh
|
$9,940
-
kW-mo/yr
|
$96 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs