Assessment Year | 2020 |
---|---|
Principal Product | Vacuum Devices |
NAICS | 333242: Semiconductor Machinery Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $100 M to 500M |
# of Employees | 306 |
Plant Area |
230,000
ft2
|
Annual Production | 200,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $96,200 | 1,442,100 |
kWh
|
$0.067 | |
Electricity Demand | $11,105 | 3,952 |
kW-mo/yr
|
$2.81 | |
Electricity Fees | $12,932 | - |
|
- | |
Natural Gas | $23,292 | 3,118 |
MMBtu
|
$7.47 | |
Waste Disposal Costs | |||||
Water Usage | $9,918 | 694 |
Tgal
|
$14.29 | |
Water Disposal | $7,836 | 694 |
Tgal
|
$11.29 | |
TOTAL YEARLY COSTS | $161,283 | ||||
RECOMMENDED SAVINGS* | $30,146 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $19,999 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $8,201 | $9,500 |
$8,201
122,951
kWh
|
- | - | - | - | - | |
02 | 3.5131: Recycle white water | $6,078 | $6,252 |
$(-608.0)
(-9,115)
kWh
|
- | - |
$1,984
-
Tgal
|
$4,702
-
Tgal
|
- | |
03 | 2.7135: Install occupancy sensors | $4,217 | $9,054 |
$3,787
56,782
kWh
|
$430
-
kW-mo/yr
|
- | - | - | - | |
04 | 3.4151: Minimize water usage | $3,145 | $2,100 | - | - | - |
$2,597
-
Tgal
|
$2,052
-
Tgal
|
$(-1,504.0) | |
05 | 2.3191: Use demand controller or load shedder | $1,832 | $4,720 | - |
$1,832
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.6232: Install set-back timers | $1,823 | $222 | - | - |
$1,823
-
MMBtu
|
- | - | - | |
07 | 2.4224: Upgrade controls on compressors | $1,361 | $3,757 |
$1,361
20,407
kWh
|
- | - | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $964 | $3,240 |
$891
13,351
kWh
|
$73
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.4322: Use or replace with energy efficient substitutes | $829 | $3,850 |
$767
11,495
kWh
|
$62
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $723 | $1,312 |
$684
10,260
kWh
|
$39
-
kW-mo/yr
|
- | - | - | - | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $397 | $36 |
$374
5,604
kWh
|
$23
-
kW-mo/yr
|
- | - | - | - | |
12 | 2.4151: Develop a repair/replace policy | $372 | $303 |
$480
7,195
kWh
|
- | - | - | - | $(-108.0) | |
13 | 2.2511: Insulate bare equipment | $157 | $742 | - | - |
$157
-
MMBtu
|
- | - | - | |
14 | 2.1233: Analyze flue gas for proper air/fuel ratio | $47 | $250 | - | - |
$83
-
MMBtu
|
- | - | $(-36.0) | |
TOTAL RECOMMENDED | $30,146 | $45,338 |
$15,937
238,930
kWh
|
$2,459
-
kW-mo/yr
|
$2,063
-
MMBtu
|
$4,581
-
Tgal
|
$6,754
-
Tgal
|
$(-1,648.0) | ||
TOTAL IMPLEMENTED | $19,999 | $26,509 |
$14,417
216,143
kWh
|
$565
-
kW-mo/yr
|
$1,980
-
MMBtu
|
$2,597
-
Tgal
|
$2,052
-
Tgal
|
$(-1,612.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings |