Assessment Year | 1988 |
---|---|
Principal Product | SMALL PLASTIC PARTS |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $152,364 | 1,954,865 |
kWh
|
$0.078 |
Fuel Oil #2 | $12,920 | 1,918 |
MMBtu
|
$6.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,259 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,361 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $834 | $322 |
$834
10,844
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $654 | $202 |
$654
8,499
kWh
|
- | |
03 | 2.6232: Install set-back timers | $1,898 | - |
$1,898
24,326
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,940 | - |
$1,940
24,912
kWh
|
- | |
05 | 2.7442: Keep doors and windows shut when not on use | $933 | - | - |
$933
-
MMBtu
|
|
TOTAL RECOMMENDED | $6,259 | $524 |
$5,326
68,581
kWh
|
$933
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,361 | $524 |
$3,428
44,255
kWh
|
$933
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs