Assessment Year 2024
Principal Product Boats, small boat components
NAICS 336612: Boat Building
SIC 3732: Boat Building and Repairing
Sales Range $100
M
to 500
M
# of Employees 100
Plant Area 157,000
ft2
Annual Production 1,500
units
Production Hrs. Annual 2,600
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $58,324 1,592,659
kWh
Electricity Demand $173,990 5,502
kW-mo/yr
Electricity Fees $27,762 -
Natural Gas $80,882 34,612
MMBtu
Waste Disposal Costs
Water Usage $3,751 484
Tgal
TOTAL YEARLY COSTS $344,709
RECOMMENDED SAVINGS* $130,666 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.3212: Optimize plant power factor $5,152 $9,744 - - $5,152 - -
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $21,143 $109,752 $(-8,650.1)
(-216,253)
kWh
- - $29,794
-
MMBtu
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,582 $6,438 $1,631
40,767
kWh
$5,951
-
kW-mo/yr
- - -
04 2.4221: Install compressor air intakes in coolest locations $2,514 $2,370 $541
13,516
kWh
$1,973
-
kW-mo/yr
- - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $2,409 - $537
13,431
kWh
$1,872
-
kW-mo/yr
- - -
06 2.4322: Use or replace with energy efficient substitutes $19,524 $98,469 $419
10,481
kWh
$5,850
-
kW-mo/yr
- $6,555
-
MMBtu
$6,700
07 2.6218: Turn off equipment when not in use $22 $66 $3
83
kWh
$19
-
kW-mo/yr
- - -
08 2.6218: Turn off equipment when not in use $603 - $290
7,253
kWh
$313
-
kW-mo/yr
- - -
09 2.6232: Install set-back timers $41,716 $119,375 $2,792
69,799
kWh
$25,815
-
kW-mo/yr
- $13,109
-
MMBtu
-
10 2.7111: Reduce illumination to minimum necessary levels $1,056 - $227
5,678
kWh
$828
-
kW-mo/yr
- - -
11 2.7135: Install occupancy sensors $2,868 $2,604 $617
15,435
kWh
$2,251
-
kW-mo/yr
- - -
12 2.7142: Utilize higher efficiency lamps and/or ballasts $292 $800 $140
3,504
kWh
$152
-
kW-mo/yr
- - -
13 2.7224: Reduce space conditioning during non-working hours $5,114 - $1,075
26,884
kWh
$3,923
-
kW-mo/yr
- $115
-
MMBtu
-
14 2.7261: Install timers and/or thermostats $61 $264 - - - $61
-
MMBtu
-
15 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $10,501 $29,043 - - - $10,501
-
MMBtu
-
16 2.7444: Close holes and openings in building such as broken windows $72 $174 - - - $72
-
MMBtu
-
17 2.7447: Install vinyl strip / high speed / air curtain doors $4,296 $25,585 $(-145.9)
(-3,648)
kWh
$(-480.6)
-
kW-mo/yr
- $4,922
-
MMBtu
-
18 2.7491: Insulate glazing, walls, ceilings, and roofs $589 $1,046 - - - $589
-
MMBtu
-
19 2.8121: Apply for tax-free status for energy purchases $5,152 - - - $5,152 - -
TOTAL RECOMMENDED $130,666 $405,730 $(-523.1)
(-13,069)
kWh
$48,466
-
kW-mo/yr
$10,304 $65,719
-
MMBtu
$6,700
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs