Assessment Year | 1983 |
---|---|
Principal Product | CARDBOARD MILK CONTAINER |
NAICS |
n/a
|
SIC | 2656: Sanitary Food Containers, Except Folding |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 30,000
ton
|
Production Hrs. Annual | 4,128
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $177,283 | 2,822,392 |
kWh
|
$0.063 |
Natural Gas | $118,464 | 30,383 |
MMBtu
|
$3.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,952 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,062 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,556 | $8,044 |
$8,556
139,215
kWh
|
- | - | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,062 | $371 | - |
$1,062
-
MMBtu
|
- | |
03 | 2.7261: Install timers and/or thermostats | $2,886 | $162 |
$234
3,810
kWh
|
$2,652
-
MMBtu
|
- | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $615 | $300 | - |
$615
-
MMBtu
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $580 | $510 | - |
$580
-
MMBtu
|
- | |
06 | 2.1123: Install automatic stack damper | $1,331 | $1,700 | - |
$1,331
-
MMBtu
|
- | |
07 | 2.6214: Shut off pilots in standby equipment | $2,452 | $300 | - |
$2,752
-
MMBtu
|
$(-300.0) | |
08 | 2.7229: Air condition only space necessary | $4,385 | - | - |
$4,385
-
MMBtu
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $360 | $252 |
$360
5,862
kWh
|
- | - | |
10 | 2.7226: Use computer programs to optimize hvac performance | $6,750 | $7,400 |
$6,750
109,906
kWh
|
- | - | |
11 | 2.7111: Reduce illumination to minimum necessary levels | $3,711 | - |
$3,711
37,222
kWh
|
- | - | |
12 | 2.6232: Install set-back timers | $2,264 | - |
$2,264
21,395
kWh
|
- | - | |
TOTAL RECOMMENDED | $34,952 | $19,039 |
$21,875
317,410
kWh
|
$13,377
-
MMBtu
|
$(-300.0) | ||
TOTAL IMPLEMENTED | $1,062 | $371 | - |
$1,062
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs