Assessment Year | 2018 |
---|---|
Principal Product | Hard aluminum extrusion |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
90,000
ft2
|
Annual Production | 6,000,000
units
|
Production Hrs. Annual | 8,520
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $925,011 | 10,733,360 |
kWh
|
$0.086 | |
Electricity Demand | $140,278 | 26,219 |
kW-mo/yr
|
$5.35 | |
Electricity Fees | $63,797 | - |
|
- | |
Natural Gas | $142,097 | 26,257 |
MMBtu
|
$5.41 | |
Waste Disposal Costs | |||||
Water Usage | $5,223 | 522 |
Tgal
|
$10.00 | |
Water Disposal | $2,559 | 522 |
Tgal
|
$4.90 | |
TOTAL YEARLY COSTS | $1,278,965 | ||||
RECOMMENDED SAVINGS* | $513,525 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $229,273 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $229,273 | $13,000 |
$212,373
2,492,646
kWh
|
$16,900
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $141,718 | $198,093 |
$130,112
1,509,418
kWh
|
$11,606
-
kW-mo/yr
|
- | - | - | - | |
03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $108,000 | $34,970 | - | - | - | - | - | $108,000 | |
04 | 2.9113: Use solar heat for heat | $15,016 | $6,034 | - | - |
$15,016
-
MMBtu
|
- | - | - | |
05 | 2.7145: Install skylights | $14,020 | $33,868 |
$14,020
162,647
kWh
|
- | - | - | - | - | |
06 | 3.4115: Recover and reuse cooling water | $3,500 | $2,576 | - | - | - |
$2,349
-
Tgal
|
$1,151
-
Tgal
|
- | |
07 | 2.2514: Cover open tanks | $1,285 | - | - | - |
$1,285
-
MMBtu
|
- | - | - | |
08 | 2.7229: Air condition only space necessary | $713 | $312 |
$656
7,607
kWh
|
$57
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $513,525 | $288,853 |
$357,161
4,172,318
kWh
|
$28,563
-
kW-mo/yr
|
$16,301
-
MMBtu
|
$2,349
-
Tgal
|
$1,151
-
Tgal
|
$108,000 | ||
TOTAL IMPLEMENTED | $229,273 | $13,000 |
$212,373
2,492,646
kWh
|
$16,900
-
kW-mo/yr
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs