ITAC Assessment: AS0458
ITAC logo
ITAC Assessment: AS0458
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Hard aluminum extrusion
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3354: Aluminum Extruded Products
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area 90,000
ft2
Annual Production 6,000,000
units
Production Hrs. Annual 8,520
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $925,011 10,733,360
kWh
Electricity Demand $140,278 26,219
kW-mo/yr
Electricity Fees $63,797 -
Natural Gas $142,097 26,257
MMBtu
Waste Disposal Costs
Water Usage $5,223 522
Tgal
Water Disposal $2,559 522
Tgal
TOTAL YEARLY COSTS $1,278,965
RECOMMENDED SAVINGS* $513,525 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $229,273

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
01 2.6218: Turn off equipment when not in use $229,273 $13,000 $212,373
2,492,646
kWh
$16,900
-
kW-mo/yr
- - - -
02 2.4133: Use most efficient type of electric motors $141,718 $198,093 $130,112
1,509,418
kWh
$11,606
-
kW-mo/yr
- - - -
03 3.6193: Install equipment (eg compactor) to reduce disposal costs $108,000 $34,970 - - - - - $108,000
04 2.9113: Use solar heat for heat $15,016 $6,034 - - $15,016
-
MMBtu
- - -
05 2.7145: Install skylights $14,020 $33,868 $14,020
162,647
kWh
- - - - -
06 3.4115: Recover and reuse cooling water $3,500 $2,576 - - - $2,349
-
Tgal
$1,151
-
Tgal
-
07 2.2514: Cover open tanks $1,285 - - - $1,285
-
MMBtu
- - -
08 2.7229: Air condition only space necessary $713 $312 $656
7,607
kWh
$57
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $513,525 $288,853 $357,161
4,172,318
kWh
$28,563
-
kW-mo/yr
$16,301
-
MMBtu
$2,349
-
Tgal
$1,151
-
Tgal
$108,000
TOTAL IMPLEMENTED $229,273 $13,000 $212,373
2,492,646
kWh
$16,900
-
kW-mo/yr
- - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs