96
matching recommendations
$
$
ARC | 2+ Digits Required | |
NAICS | 3+ Digits Required | |
SIC | Electric lamp bulbs and tubes | |
3+ Characters Required for Products |
ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
---|---|---|---|---|---|---|
NC0577 #09 Y:2016 | 09 | 2016 | Treat and reuse rinse waters | $5,659 | $7,720 | |
NC0577 #08 Y:2016 | 08 | 2016 | Repair and eliminate steam leaks | $106 | $200 | |
NC0577 #07 Y:2016 | 07 | 2016 | Insulate bare equipment | $168 | $799 | |
NC0577 #06 Y:2016 | 06 | 2016 | Eliminate or reduce compressed air usage | $1,793 | $2,000 | |
NC0577 #05 Y:2016 | 05 | 2016 | Reduce the pressure of compressed air to the minimum required | $2,896 | $100 | |
NC0577 #04 Y:2016 | 04 | 2016 | Eliminate or reduce compressed air usage | $1,088 | $3,600 | |
NC0577 #03 Y:2016 | 03 | 2016 | Eliminate leaks in inert gas and compressed air lines/ valves | $819 | $100 | |
NC0577 #02 Y:2016 | 02 | 2016 | Use direct air supply to exhaust hoods | $11,227 | $15,000 | |
NC0577 #01 Y:2016 | 01 | 2016 | Utilize higher efficiency lamps and/or ballasts | $59,300 | $135,630 | |
TT0050 #06 Y:2010 | 06 | 2010 | Install occupancy sensors | $500 | $400 | |
TT0050 #05 Y:2010 | 05 | 2010 | Utilize controls to operate equipment only when needed | $2,200 | - | |
TT0050 #04 Y:2010 | 04 | 2010 | Lower temperature during the winter season and vice-versa | $4,900 | $500 | |
TT0050 #03 Y:2010 | 03 | 2010 | Use optimum thickness insulation | $6,800 | $1,000 | |
TT0050 #02 Y:2010 | 02 | 2010 | Eliminate or reduce compressed air usage | $40,479 | $4,300 | |
TT0050 #01 Y:2010 | 01 | 2010 | Eliminate leaks in inert gas and compressed air lines/ valves | $40,500 | $2,900 | |
TA0026 #07 Y:2002 | 07 | 2002 | Lower ceiling to reduce conditioned space | $214 | - | |
TA0026 #06 Y:2002 | 06 | 2002 | Recharge batteries on during off-peak demand periods | $500 | - | |
TA0026 #05 Y:2002 | 05 | 2002 | Install occupancy sensors | $875 | $346 | |
TA0026 #04 Y:2002 | 04 | 2002 | Insulate bare equipment | $980 | $400 | |
TA0026 #03 Y:2002 | 03 | 2002 | Turn off equipment during breaks, reduce operating time | $1,230 | - |