445
matching recommendations
$
$
| ARC | 2+ Digits Required | |
| NAICS | 3+ Digits Required | |
| SIC | Secondary smelting and refining of nonferrous metals | |
| 3+ Characters Required for Products | ||
| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| LE0610 #07 Y:2026 | 07 | 2026 | Replace existing hvac unit with high efficiency model | $51,154 | $342,500 |
n/a
|
| LE0610 #06 Y:2026 | 06 | 2026 | Replace existing chiller with high efficiency model | $116,186 | $277,439 |
n/a
|
| LE0610 #05 Y:2026 | 05 | 2026 | Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,210 | $3,880 |
n/a
|
| LE0610 #04 Y:2026 | 04 | 2026 | Eliminate leaks in inert gas and compressed air lines/ valves | $12,801 | $10,000 |
n/a
|
| LE0610 #03 Y:2026 | 03 | 2026 | Repair or replace steam traps | $24,632 | $10,000 |
n/a
|
| LE0610 #02 Y:2026 | 02 | 2026 | Install occupancy sensors | $1,327 | $200 |
n/a
|
| LE0610 #01 Y:2026 | 01 | 2026 | Eliminate leaks in inert gas and compressed air lines/ valves | $44,729 | $4,400 |
n/a
|
| SF0584 #06 Y:2022 | 06 | 2022 | Use solar heat to make electricty | $123,728 | $381,839 | |
| SF0584 #05 Y:2022 | 05 | 2022 | Eliminate or reduce compressed air usage | $6,260 | $23,959 | |
| SF0584 #04 Y:2022 | 04 | 2022 | Use adjustable frequency drive or multiple speed motors on existing system | $8,188 | $24,576 | |
| SF0584 #03 Y:2022 | 03 | 2022 | Utilize higher efficiency lamps and/or ballasts | $8,882 | $13,939 | |
| SF0584 #02 Y:2022 | 02 | 2022 | Use adjustable frequency drive or multiple speed motors on existing system | $5,093 | $4,749 | |
| SF0584 #01 Y:2022 | 01 | 2022 | Reduce space conditioning during non-working hours | $9,346 | $2,177 | |
| TT0242 #06 Y:2020 | 06 | 2020 | Install timers and/or thermostats | $1,854 | $1,700 | |
| TT0242 #05 Y:2020 | 05 | 2020 | Eliminate leaks in inert gas and compressed air lines/ valves | $4,251 | $263 | |
| TT0242 #04 Y:2020 | 04 | 2020 | Meter recycled water (to reduce sewer charges) | $13,945 | $1,900 | |
| TT0242 #03 Y:2020 | 03 | 2020 | Utilize higher efficiency lamps and/or ballasts | $24,394 | $110,050 | |
| TT0242 #02 Y:2020 | 02 | 2020 | Eliminate leaks in inert gas and compressed air lines/ valves | $31,412 | $62,026 | |
| TT0242 #01 Y:2020 | 01 | 2020 | Change procedures / equipment / operating conditions | $1,906,442 | $4,500,000 | |
| UA0209 #05 Y:2019 | 05 | 2019 | Size electric motors for peak operating efficiency | $1,176 | $1,200 |