Assessment Year | 2020 |
---|---|
Principal Product | Aluminum Ingots |
NAICS | 331314: Secondary Smelting and Alloying of Aluminum |
SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
140,000
ft2
|
Annual Production | 46,450
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $540,606 | 9,665,003 |
kWh
|
$0.056 | |
Electricity Demand | $256,691 | 19,033 |
kW-mo/yr
|
$13.49 | |
Natural Gas | $524,260 | 143,004 |
MMBtu
|
$3.67 | |
Waste Disposal Costs | |||||
Water Usage | $14,072 | 2,206 |
Tgal
|
$6.38 | |
Water Disposal | $17,491 | 2,206 |
Tgal
|
$7.93 | |
TOTAL YEARLY COSTS | $1,353,120 | ||||
RECOMMENDED SAVINGS* | $1,982,298 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,906,442 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1191: Change procedures / equipment / operating conditions | $1,906,442 | $4,500,000 |
$88,633
1,585,560
kWh
|
$29,300
-
kW-mo/yr
|
$26,009
-
MMBtu
|
- | $1,762,500 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $31,412 | $62,026 | - | - | - | - | $31,412 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,394 | $110,050 |
$17,304
309,570
kWh
|
$7,090
-
kW-mo/yr
|
- | - | - | |
04 | 3.4116: Meter recycled water (to reduce sewer charges) | $13,945 | $1,900 | - | - | - |
$13,945
-
Tgal
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,251 | $263 |
$4,251
76,038
kWh
|
- | - | - | - | |
06 | 2.7261: Install timers and/or thermostats | $1,854 | $1,700 |
$1,530
27,371
kWh
|
- |
$324
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $1,982,298 | $4,675,938 |
$111,718
1,998,539
kWh
|
$36,390
-
kW-mo/yr
|
$26,333
-
MMBtu
|
$13,945
-
Tgal
|
$1,793,912 | ||
TOTAL IMPLEMENTED | $1,906,442 | $4,500,000 |
$88,633
1,585,560
kWh
|
$29,300
-
kW-mo/yr
|
$26,009
-
MMBtu
|
- | $1,762,500 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs