77
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| UD1142 #07 Y:2026 | 07 | 2026 | Install vinyl strip / high speed / air curtain doors | $2,469 | $8,240 |
n/a
|
| UD1142 #06 Y:2026 | 06 | 2026 | Install occupancy sensors | $1,317 | $2,481 |
n/a
|
| UD1142 #05 Y:2026 | 05 | 2026 | Disconnect ballasts | $14,992 | $20,812 |
n/a
|
| UD1142 #04 Y:2026 | 04 | 2026 | Eliminate leaks in inert gas and compressed air lines/ valves | $382 | $953 |
n/a
|
| UD1142 #03 Y:2026 | 03 | 2026 | Reduce the pressure of compressed air to the minimum required | $1,190 | - |
n/a
|
| UD1142 #02 Y:2026 | 02 | 2026 | Eliminate or reduce compressed air usage | $2,261 | $32 |
n/a
|
| UD1142 #01 Y:2026 | 01 | 2026 | Utilize energy-efficient belts and other improved mechanisms | $469 | - |
n/a
|
| GT1010 #07 Y:2026 | 07 | 2026 | Use solar heat to make electricty | $49,377 | $1,123,789 |
n/a
|
| GT1010 #06 Y:2026 | 06 | 2026 | Replace existing hvac unit with high efficiency model | $33,339 | $501,250 |
n/a
|
| GT1010 #05 Y:2026 | 05 | 2026 | Replace fossil fuel equipment with electrical equipment | $8,013 | $91,000 |
n/a
|
| GT1010 #04 Y:2026 | 04 | 2026 | Install occupancy sensors | $5,485 | $19,955 |
n/a
|
| GT1010 #03 Y:2026 | 03 | 2026 | Utilize higher efficiency lamps and/or ballasts | $6,809 | $15,278 |
n/a
|
| GT1010 #02 Y:2026 | 02 | 2026 | Reduce space conditioning during non-working hours | $11,999 | $5,850 |
n/a
|
| GT1010 #01 Y:2026 | 01 | 2026 | Pay bills on time to avoid late fees | $6,059 | $50 |
n/a
|
| MZ1023 #09 Y:2026 | 09 | 2026 | Use steam sparging or injections in place of indirect heating | $163,794 | $190,000 |
n/a
|
| MZ1023 #08 Y:2026 | 08 | 2026 | Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $81,881 | $665,000 |
n/a
|
| MZ1023 #07 Y:2026 | 07 | 2026 | Utilize controls to operate equipment only when needed | $1,311 | $2,140 |
n/a
|
| MZ1023 #06 Y:2026 | 06 | 2026 | Insulate bare equipment | $31,375 | $16,500 |
n/a
|
| MZ1023 #05 Y:2026 | 05 | 2026 | Recover heat from exhausted steam, hot air or hot water | $13,206 | $54,300 |
n/a
|
| MZ1023 #04 Y:2026 | 04 | 2026 | Level zero – install control systems for existing equipment | $47,010 | $41,600 |
n/a
|