ITAC Assessment: OK1178
ITAC logo
ITAC Assessment: OK1178
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Business services: expositions, conferences, workshops, & meetings
NAICS 561920: Convention and Trade Show Organizers
SIC 7389: Business Services, Not Elsewhere Classified
Sales Range $500
k
to 1
M
# of Employees 20
Plant Area 140,000
ft2
Annual Production 1
units
Production Hrs. Annual 3,120
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $145,335 2,242,800
kWh
Electricity Demand $38,923 4,770
kW-mo/yr
Natural Gas $9,259 1,440
MMBtu
Waste Disposal Costs
Water Usage $8,180 1,716
Tgal
Water Disposal $8,180 1,716
Tgal
TOTAL YEARLY COSTS $209,877
RECOMMENDED SAVINGS* $49,063 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings
01 2.9114: Use solar heat to make electricty $19,887 $289,920 $19,887
305,943
kWh
- -
02 2.3212: Optimize plant power factor $1,207 $2,699 - - $1,207
03 2.7142: Utilize higher efficiency lamps and/or ballasts $11,495 $42,458 $7,749
119,220
kWh
$3,746
-
kW-mo/yr
-
04 2.7135: Install occupancy sensors $11,237 $3,916 $11,237
172,883
kWh
- -
05 2.7211: Clean and maintain refrigerant condensers and towers $5,237 $4,365 $5,237
80,574
kWh
- -
TOTAL RECOMMENDED $49,063 $343,358 $44,110
678,620
kWh
$3,746
-
kW-mo/yr
$1,207
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs