| Assessment Year | 1996 |
|---|---|
| Principal Product | Custom Semiconductors |
| NAICS |
n/a
|
| SIC | 3674: Semiconductors and Related Devices |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
72,740
ft2
|
| Annual Production | 230,000
pieces
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Arizona |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $496,982 | 8,512,310 |
kWh
|
$0.058 |
| Electricity Demand | $41,566 | 14,772 |
kW-mo/yr
|
$2.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $37,502 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,672 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7241: Install outside air damper / economizer on hvac unit | $14,536 | $7,000 |
$14,536
249,121
kWh
|
- | - | |
| 02 | 2.7261: Install timers and/or thermostats | $2,116 | $3,200 |
$2,116
36,342
kWh
|
- | - | |
| 03 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $4,440 | $20,000 |
$4,440
76,202
kWh
|
- | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $3,906 | $2,211 |
$3,653
62,427
kWh
|
$253
-
kW-mo/yr
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,348 | - |
$1,257
21,688
kWh
|
$91
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,288 | - |
$1,288
21,981
kWh
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $2,105 | $1,200 |
$2,105
36,049
kWh
|
- | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,873 | $11,962 |
$5,252
89,977
kWh
|
$621
-
kW-mo/yr
|
- | |
| 09 | 3.4151: Minimize water usage | $1,890 | $491 | - | - |
$1,890
-
Tgal
|
|
| TOTAL RECOMMENDED | $37,502 | $46,064 |
$34,647
593,787
kWh
|
$965
-
kW-mo/yr
|
$1,890
-
Tgal
|
||
| TOTAL IMPLEMENTED | $17,672 | $35,373 |
$16,707
286,343
kWh
|
$965
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs