| Assessment Year | 2026 |
|---|---|
| Principal Product | Management services |
| NAICS | 561110: Office Administrative Services |
| SIC | 8741: Management Services |
| Sales Range | $500 k to 1M |
| # of Employees | 50 |
| Plant Area |
42,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $42,566 | 596,720 |
kWh
|
$0.071 | |
| Electricity Demand | $15,542 | 1,905 |
kW-mo/yr
|
$8.16 | |
| Natural Gas | $5,189 | 497 |
MMBtu
|
$10.44 | |
| Waste Disposal Costs | |||||
| Water Usage | $6,728 | 1,338 |
Tgal
|
$5.03 | |
| Water Disposal | $6,728 | 1,338 |
Tgal
|
$5.03 | |
| TOTAL YEARLY COSTS | $76,753 | ||||
| RECOMMENDED SAVINGS* | $13,800 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,620 | $18,584 |
$3,670
51,688
kWh
|
$1,950
-
kW-mo/yr
|
|
| 02 | 2.7135: Install occupancy sensors | $886 | $633 |
$886
12,485
kWh
|
- | |
| 03 | 2.7232: Replace existing hvac unit with high efficiency model | $422 | $1,815 |
$422
5,939
kWh
|
- | |
| 04 | 2.7211: Clean and maintain refrigerant condensers and towers | $4,726 | $10,910 |
$4,726
66,557
kWh
|
- | |
| 05 | 2.6211: Conserve energy by efficient use of vending machines | $2,146 | $1,120 |
$2,146
30,222
kWh
|
- | |
| TOTAL RECOMMENDED | $13,800 | $33,062 |
$11,850
166,891
kWh
|
$1,950
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs