681
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| OR0496 #07 Y:2005 | 07 | 2005 | Upgrade controls on compressors | $8,030 | $2,000 | |
| OR0496 #06 Y:2005 | 06 | 2005 | Use most efficient type of electric motors | $33,700 | $91,000 | |
| OR0496 #05 Y:2005 | 05 | 2005 | Optimize plant power factor | $51,400 | $28,000 | |
| OR0496 #04 Y:2005 | 04 | 2005 | Direct warmest air to combustion intake | $66,800 | $118,000 | |
| OR0496 #03 Y:2005 | 03 | 2005 | Use adjustable frequency drive or multiple speed motors on existing system | $201,300 | $301,500 | |
| OR0496 #02 Y:2005 | 02 | 2005 | Replace existing equipment with more suitable substitutes | $282,000 | $212,000 | |
| OR0496 #01 Y:2005 | 01 | 2005 | Upgrade obsolete equipment | $689,000 | $213,000 | |
| AS0407 #04 Y:2005 | 04 | 2005 | Eliminate leaks in inert gas and compressed air lines/ valves | $744 | $2,000 | |
| AS0407 #03 Y:2005 | 03 | 2005 | Reduce the pressure of compressed air to the minimum required | $989 | $2,000 | |
| AS0407 #02 Y:2005 | 02 | 2005 | Use solar heat to heat water | $1,251 | $3,200 | |
| AS0407 #01 Y:2005 | 01 | 2005 | Install equipment to move product | $257,790 | $218,456 | |
| CO0576 #08 Y:2005 | 08 | 2005 | Utilize higher efficiency lamps and/or ballasts | $920 | $1,440 | |
| CO0576 #07 Y:2005 | 07 | 2005 | Recover waste heat from equipment | $1,740 | $980 | |
| CO0576 #06 Y:2005 | 06 | 2005 | Improve air circulation with destratification fans / other methods | $4,670 | $9,240 | |
| CO0576 #05 Y:2005 | 05 | 2005 | Replace existing hvac unit with high efficiency model | $6,190 | $17,170 | |
| CO0576 #04 Y:2005 | 04 | 2005 | Utilize outside air instead of conditioned air for drying | $200 | $170 | |
| CO0576 #03 Y:2005 | 03 | 2005 | Eliminate leaks in inert gas and compressed air lines/ valves | $2,540 | $190 | |
| CO0576 #02 Y:2005 | 02 | 2005 | Shift from daytime to nighttime operation | $4,450 | - | |
| CO0576 #01 Y:2005 | 01 | 2005 | Install rotating carousels to reduce set-up times | $84,000 | $30,670 | |
| OR0489 #11 Y:2005 | 11 | 2005 | Direct warmest air to combustion intake | $8,500 | $22,000 |