Assessment Year | 2005 |
---|---|
Principal Product | Wooden trusses |
NAICS | 321214: Truss Manufacturing |
SIC | 2439: Structural Wood Members, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 52 |
Plant Area |
65,000
ft2
|
Annual Production | 7,000,000
thousand feet
|
Production Hrs. Annual | 3,048
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,797 | 273,782 |
kWh
|
$0.061 |
Electricity Demand | $2,820 | 235 |
kW-mo/yr
|
$12.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $260,774 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 4.445: Install equipment to move product | $257,790 | $218,456 | - | - | $257,790 | |
02 | 2.9112: Use solar heat to heat water | $1,251 | $3,200 |
$461
7,202
kWh
|
$790
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $989 | $2,000 |
$848
13,245
kWh
|
$141
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $744 | $2,000 |
$648
10,119
kWh
|
$96
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $260,774 | $225,656 |
$1,957
30,566
kWh
|
$1,027
-
kW-mo/yr
|
$257,790 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs