Assessment Year | 2024 |
---|---|
Principal Product | Razor Blades |
NAICS | 339112: Surgical and Medical Instrument Manufacturing |
SIC | 3841: Surgical and Medical Instruments and Apparatus |
Sales Range | $50 M to 100M |
# of Employees | 178 |
Plant Area |
290,000
ft2
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 6,400
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $506,921 | 9,748,490 |
kWh
|
$0.052 |
Electricity Demand | $159,050 | 18,712 |
kW-mo/yr
|
$8.50 |
Electricity Fees | $105,041 | - |
|
- |
Natural Gas | $101,687 | 13,233 |
MMBtu
|
$7.68 |
TOTAL YEARLY COSTS | $872,699 | |||
RECOMMENDED SAVINGS* | $100,269 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,198 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $59,309 | $62,726 |
$45,394
872,965
kWh
|
$13,915
-
kW-mo/yr
|
- | - | |
02 | 2.4224: Upgrade controls on compressors | $17,495 | $16,930 |
$12,633
242,935
kWh
|
$4,862
-
kW-mo/yr
|
- | - | |
03 | 2.1221: Replace obsolete burners with more efficient ones | $6,267 | $2,720 | - | - |
$6,267
-
MMBtu
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,213 | $1,440 |
$3,227
62,067
kWh
|
$986
-
kW-mo/yr
|
- | - | |
05 | 2.2425: Use flue gases to heat process or service water | $4,133 | $19,900 | - | - |
$4,133
-
MMBtu
|
- | |
06 | 2.4157: Establish a predictive maintenance program | $2,611 | $3,200 |
$3,299
63,449
kWh
|
$1,012
-
kW-mo/yr
|
- | $(-1,700.0) | |
07 | 2.4151: Develop a repair/replace policy | $2,399 | $4,720 |
$2,388
45,928
kWh
|
$731
-
kW-mo/yr
|
- | $(-720.0) | |
08 | 2.2511: Insulate bare equipment | $1,554 | $549 |
$896
17,240
kWh
|
- |
$658
-
MMBtu
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $915 | $120 |
$702
13,493
kWh
|
$213
-
kW-mo/yr
|
- | - | |
10 | 2.6231: Utilize controls to operate equipment only when needed | $770 | $2,660 |
$591
11,373
kWh
|
$179
-
kW-mo/yr
|
- | - | |
11 | 2.4239: Eliminate or reduce compressed air usage | $603 | $2,300 |
$458
8,811
kWh
|
$145
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $100,269 | $117,265 |
$69,588
1,338,261
kWh
|
$22,043
-
kW-mo/yr
|
$11,058
-
MMBtu
|
$(-2,420.0) | ||
TOTAL IMPLEMENTED | $17,198 | $34,889 |
$11,561
222,361
kWh
|
$3,266
-
kW-mo/yr
|
$4,791
-
MMBtu
|
$(-2,420.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |