| Assessment Year | 2023 |
|---|---|
| Principal Product | Custom Cabinetry |
| NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
| SIC | 2434: Wood Kitchen Cabinets |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
970,000
ft2
|
| Annual Production | 5,100
pieces
|
| Production Hrs. Annual | 4,590
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $42,475 | 834,390 |
kWh
|
$0.051 | |
| Electricity Demand | $42,141 | 2,857 |
kW-mo/yr
|
$14.75 | |
| Electricity Fees | $3,640 | - |
|
- | |
| LPG | $54,405 | 2,647 |
MMBtu
|
$20.55 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,493 | 145 |
Tgal
|
$10.28 | |
| Water Disposal | $977 | 145 |
Tgal
|
$6.72 | |
| TOTAL YEARLY COSTS | $145,131 | ||||
| RECOMMENDED SAVINGS* | $41,030 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $7,373 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $23,558 | $12,360 |
$13,779
254,701
kWh
|
$9,779
-
kW-mo/yr
|
- | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,092 | $29,560 |
$556
10,272
kWh
|
$398
-
kW-mo/yr
|
$5,138
-
MMBtu
|
- | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,500 | $1,023 | - | - |
$4,500
-
MMBtu
|
- | |
| 04 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $4,007 | $10,420 | - | - |
$4,007
-
MMBtu
|
- | |
| 05 | 2.4224: Upgrade controls on compressors | $954 | $1,965 |
$836
15,462
kWh
|
$118
-
kW-mo/yr
|
- | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $530 | $100 |
$309
5,707
kWh
|
$221
-
kW-mo/yr
|
- | - | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $523 | $1,573 |
$269
4,964
kWh
|
$192
-
kW-mo/yr
|
$62
-
MMBtu
|
- | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $459 | $1,293 |
$263
4,864
kWh
|
$196
-
kW-mo/yr
|
- | - | |
| 09 | 2.4151: Develop a repair/replace policy | $310 | $592 |
$200
3,695
kWh
|
$148
-
kW-mo/yr
|
- | $(-38.0) | |
| 10 | 2.6231: Utilize controls to operate equipment only when needed | $76 | $368 |
$46
841
kWh
|
$30
-
kW-mo/yr
|
- | - | |
| 11 | 2.2511: Insulate bare equipment | $21 | $31 | - | - |
$21
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $41,030 | $59,285 |
$16,258
300,506
kWh
|
$11,082
-
kW-mo/yr
|
$13,728
-
MMBtu
|
$(-38.0) | ||
| TOTAL IMPLEMENTED | $7,373 | $6,945 |
$1,923
35,533
kWh
|
$905
-
kW-mo/yr
|
$4,583
-
MMBtu
|
$(-38.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs