| Assessment Year | 2008 |
|---|---|
| Principal Product | spices and soup mixes |
| NAICS | 311942: Spice and Extract Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
120,000
ft2
|
| Annual Production | 5,000,000
lb
|
| Production Hrs. Annual | 6,600
hrs
|
| Location (State) | Puerto Rico |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $456,615 | 3,302,640 |
kWh
|
$0.14 |
| Electricity Demand | $51,378 | 6,606 |
kW-mo/yr
|
$7.78 |
| Electricity Fees | $6,753 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $89,794 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $50,966 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $20,466 | $1,032 |
$18,959
137,126
kWh
|
$1,507
-
kW-mo/yr
|
|
| 02 | 2.4323: Use optimum size and capacity equipment | $22,048 | $8,641 |
$20,165
145,806
kWh
|
$1,883
-
kW-mo/yr
|
|
| 03 | 2.7446: Utilize sensors controlling roof and wall openings | $16,476 | $474 |
$15,029
130,456
kWh
|
$1,447
-
kW-mo/yr
|
|
| 04 | 2.2628: Utilize a less expensive cooling method | $11,340 | $15,475 |
$9,971
75,100
kWh
|
$1,369
-
kW-mo/yr
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,705 | $17,226 |
$6,423
46,455
kWh
|
$1,282
-
kW-mo/yr
|
|
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,319 | $24 |
$5,806
41,993
kWh
|
$513
-
kW-mo/yr
|
|
| 07 | 2.4323: Use optimum size and capacity equipment | $5,440 | $3,411 |
$5,101
36,897
kWh
|
$339
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $89,794 | $46,283 |
$81,454
613,833
kWh
|
$8,340
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $50,966 | $18,756 |
$46,217
356,030
kWh
|
$4,749
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs