ITAC Assessment: WV0636
ITAC logo
ITAC Assessment: WV0636
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Sauna
NAICS 326191: Plastics Plumbing Fixture Manufacturing
SIC 3088: Plastics Plumbing Fixtures
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 96,000
ft2
Annual Production 8,000
units
Production Hrs. Annual 2,080
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,088 765,280
kWh
Electricity Demand $50,938 3,083
kW-mo/yr
Electricity Fees $2,388 -
Natural Gas $7,358 757
MMBtu
Other Energy $12,134 268
MMBtu
TOTAL YEARLY COSTS $108,906
RECOMMENDED SAVINGS* $36,278 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,606

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $13,183 $4,755 - $13,183
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,625 $18,739 $4,091
86,677
kWh
$5,534
-
kW-mo/yr
- -
03 2.6242: Minimize operation of equipment maintained in standby condition $4,546 $5,490 $1,506
31,909
kWh
$3,040
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,868 $465 $952
20,172
kWh
$1,916
-
kW-mo/yr
- -
05 2.4224: Upgrade controls on compressors $1,927 $2,021 $698
14,793
kWh
$1,229
-
kW-mo/yr
- -
06 2.4239: Eliminate or reduce compressed air usage $670 $78 $224
4,743
kWh
$446
-
kW-mo/yr
- -
07 2.4239: Eliminate or reduce compressed air usage $299 $465 $101
2,141
kWh
$198
-
kW-mo/yr
- -
08 2.4151: Develop a repair/replace policy $217 $598 $94
1,992
kWh
$182
-
kW-mo/yr
- $(-59.0)
09 2.7447: Install vinyl strip / high speed / air curtain doors $2,943 $7,374 $(-31.0)
(-661)
kWh
- $2,974
-
MMBtu
-
TOTAL RECOMMENDED $36,278 $39,985 $7,635
161,766
kWh
$25,728
-
kW-mo/yr
$2,974
-
MMBtu
$(-59.0)
TOTAL IMPLEMENTED $15,606 $22,366 $6,160
130,518
kWh
$9,505
-
kW-mo/yr
- $(-59.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs