| Assessment Year | 2026 |
|---|---|
| Principal Product | Engineered Agriscience Cellulose & Wood Fiber Products |
| NAICS | 322110: Pulp Mills |
| SIC | 2611: Pulp Mills |
| Sales Range | $50 M to 100M |
| # of Employees | 211 |
| Plant Area |
82,000
ft2
|
| Annual Production | 123,947
ton
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,231,205 | 26,019,746 |
kWh
|
$0.086 |
| Natural Gas | $218,040 | 330,041 |
MMBtu
|
$0.66 |
| TOTAL YEARLY COSTS | $2,449,245 | |||
| RECOMMENDED SAVINGS* | $534,729 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $40,202 | $1,850 |
$43,102
501,189
kWh
|
- | $(-2,900.0) | |
| 02 | 2.7135: Install occupancy sensors | $1,240 | $930 |
$1,240
14,422
kWh
|
- | - | |
| 03 | 2.2511: Insulate bare equipment | $3,807 | $4,806 | - |
$3,807
-
MMBtu
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,772 | $20,582 |
$7,772
90,377
kWh
|
- | - | |
| 05 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $366,345 | $1,207,500 |
$376,680
4,380,000
kWh
|
$(-10,335.0)
-
MMBtu
|
- | |
| 06 | 2.9114: Use solar heat to make electricty | $115,363 | $829,891 |
$115,363
1,345,339
kWh
|
- | - | |
| TOTAL RECOMMENDED | $534,729 | $2,065,559 |
$544,157
6,331,327
kWh
|
$(-6,528.0)
-
MMBtu
|
$(-2,900.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs