Assessment Year | 2022 |
---|---|
Principal Product | Construction Equipment |
NAICS | 333120: Construction Machinery Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $50 M to 100M |
# of Employees | 480 |
Plant Area |
800,000
ft2
|
Annual Production | 1,500
units
|
Production Hrs. Annual | 2,880
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $266,094 | 6,087,333 |
kWh
|
$0.044 | |
Electricity Demand | $208,747 | 22,228 |
kW-mo/yr
|
$9.39 | |
Electricity Fees | $11,938 | - |
|
- | |
Natural Gas | $286,598 | 26,180 |
MMBtu
|
$10.95 | |
Waste Disposal Costs | |||||
Water Usage | $111,002 | 7,255 |
Tgal
|
$15.30 | |
TOTAL YEARLY COSTS | $884,379 | ||||
RECOMMENDED SAVINGS* | $277,108 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $196,251 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $72,629 | $104,885 |
$38,224
874,693
kWh
|
$34,405
-
kW-mo/yr
|
- | - | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $61,441 | $127,733 |
$1,899
43,453
kWh
|
$554
-
kW-mo/yr
|
$58,988
-
MMBtu
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $51,704 | $257,600 |
$27,281
624,270
kWh
|
$24,423
-
kW-mo/yr
|
- | - | - | |
04 | 3.5131: Recycle white water | $19,492 | $11,082 |
$(-172.0)
(-3,944)
kWh
|
- | - |
$19,664
-
Tgal
|
- | |
05 | 2.1321: Replace fossil fuel equipment with electrical equipment | $19,461 | $91,800 |
$(-8,178.0)
(-187,129)
kWh
|
$(-7,324.0)
-
kW-mo/yr
|
$34,963
-
MMBtu
|
- | - | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $14,348 | $3,600 | - |
$14,348
-
kW-mo/yr
|
- | - | - | |
07 | 2.7313: Recycle air for heating, ventilation and air conditioning | $12,693 | $51,500 |
$2,570
58,800
kWh
|
$2,301
-
kW-mo/yr
|
$28,350
-
MMBtu
|
- | $(-20,528.0) | |
08 | 2.7314: Reduce ventilation air | $8,396 | $19,558 |
$90
2,058
kWh
|
$28
-
kW-mo/yr
|
$8,278
-
MMBtu
|
- | - | |
09 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $6,154 | $13,600 | - | - |
$6,154
-
MMBtu
|
- | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $2,877 | $2,813 |
$1,515
34,680
kWh
|
$1,362
-
kW-mo/yr
|
- | - | - | |
11 | 2.4224: Upgrade controls on compressors | $1,756 | $299 |
$1,756
40,188
kWh
|
- | - | - | - | |
12 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,660 | $3,000 | - | - |
$1,960
-
MMBtu
|
- | $(-300.0) | |
13 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,487 | $990 |
$1,040
23,800
kWh
|
$447
-
kW-mo/yr
|
- | - | - | |
14 | 2.4151: Develop a repair/replace policy | $1,356 | $2,300 |
$845
19,349
kWh
|
$751
-
kW-mo/yr
|
- | - | $(-240.0) | |
15 | 2.4224: Upgrade controls on compressors | $1,341 | $4,835 |
$900
20,598
kWh
|
$441
-
kW-mo/yr
|
- | - | - | |
16 | 2.4157: Establish a predictive maintenance program | $313 | $1,500 |
$1,203
27,518
kWh
|
$1,080
-
kW-mo/yr
|
- | - | $(-1,970.0) | |
TOTAL RECOMMENDED | $277,108 | $697,095 |
$68,973
1,578,334
kWh
|
$72,816
-
kW-mo/yr
|
$138,693
-
MMBtu
|
$19,664
-
Tgal
|
$(-23,038.0) | ||
TOTAL IMPLEMENTED | $196,251 | $504,455 |
$73,460
1,681,031
kWh
|
$62,383
-
kW-mo/yr
|
$60,948
-
MMBtu
|
- | $(-540.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs