Assessment Year 2019
Principal Product Galvanized Steel Sheets
NAICS 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3496: Miscellaneous Fabricated Wire Products
Sales Range $100
M
to 500
M
# of Employees 64
Plant Area 128,509
ft2
Annual Production 300,000
ton
Production Hrs. Annual 8,568
hrs
Location (State) Pennsylvania
View Case Study

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $582,312 9,968,579
kWh
Electricity Demand $208,147 22,427
kW-mo/yr
Electricity Fees $(-8,830.0) -
Natural Gas $1,101,170 286,726
MMBtu
Waste Disposal Costs
Water Usage $44,162 3,994
Tgal
Water Disposal $29,467 4,904
Tgal
TOTAL YEARLY COSTS $1,956,428
RECOMMENDED SAVINGS* $237,497 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $71,466

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings Personnel Changes Savings
01 2.1221: Replace obsolete burners with more efficient ones $128,494 $314,600 - - $128,494
-
MMBtu
- - -
02 2.2524: Avoid cooling of process streams or materials that must subsequently be heated $37,537 $5,500 $(-632.0)
(-10,828)
kWh
$(-139.0)
-
kW-mo/yr
$38,308
-
MMBtu
- - -
03 2.4322: Use or replace with energy efficient substitutes $28,868 $78,000 $23,616
404,838
kWh
$5,252
-
kW-mo/yr
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $17,233 $58,107 $13,382
229,141
kWh
$3,851
-
kW-mo/yr
- - - -
05 2.4224: Upgrade controls on compressors $9,387 $4,000 $9,387
160,732
kWh
- - - - -
06 3.5131: Recycle white water $8,651 $4,100 $(-373.0)
(-6,392)
kWh
- - $5,743
-
Tgal
$3,281
-
Tgal
-
07 2.4151: Develop a repair/replace policy $4,849 $738 $4,302
73,660
kWh
$947
-
kW-mo/yr
- - - $(-400.0)
08 2.4231: Reduce the pressure of compressed air to the minimum required $1,540 $100 $1,262
21,603
kWh
$278
-
kW-mo/yr
- - - -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $938 - $771
13,203
kWh
$167
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $237,497 $465,145 $51,715
885,957
kWh
$10,356
-
kW-mo/yr
$166,802
-
MMBtu
$5,743
-
Tgal
$3,281
-
Tgal
$(-400.0)
TOTAL IMPLEMENTED $71,466 $145,045 $52,347
896,785
kWh
$10,495
-
kW-mo/yr
- $5,743
-
Tgal
$3,281
-
Tgal
$(-400.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings Personnel Changes Savings