Assessment Year | 2005 |
---|---|
Principal Product | Radiators |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
40,000
ft2
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,314 | 1,505,520 |
kWh
|
$0.033 |
Electricity Demand | $40,904 | 4,374 |
kW-mo/yr
|
$9.35 |
Electricity Fees | $18,298 | - |
|
- |
Natural Gas | $40,774 | 5,204 |
MMBtu
|
$7.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,971 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,513 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,912 | $11,200 |
$3,632
102,900
kWh
|
$2,280
-
kW-mo/yr
|
- | - | |
02 | 2.7144: Install spectral reflectors / delamp | $933 | - |
$573
16,236
kWh
|
$360
-
kW-mo/yr
|
- | - | |
03 | 2.7313: Recycle air for heating, ventilation and air conditioning | $5,262 | $5,600 | - | - |
$5,262
-
MMBtu
|
- | |
04 | 2.4239: Eliminate or reduce compressed air usage | $1,836 | $780 |
$84
2,378
kWh
|
$1,752
-
kW-mo/yr
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $714 | $1,280 |
$430
12,187
kWh
|
$284
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $334 | $400 |
$334
9,462
kWh
|
- | - | - | |
07 | 2.7261: Install timers and/or thermostats | $1,350 | $1,200 | - | - |
$1,350
-
MMBtu
|
- | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,185 | $1,400 |
$(-9.0)
(-252)
kWh
|
- |
$1,194
-
MMBtu
|
- | |
09 | 4.821: Pay bills on time to avoid late fees | $1,172 | - | - | - | - | $1,172 | |
10 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,165 | $3,000 |
$686
19,440
kWh
|
$479
-
kW-mo/yr
|
- | - | |
11 | 2.2514: Cover open tanks | $1,108 | $360 | - | - |
$1,108
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $20,971 | $25,220 |
$5,730
162,351
kWh
|
$5,155
-
kW-mo/yr
|
$8,914
-
MMBtu
|
$1,172 | ||
TOTAL IMPLEMENTED | $17,513 | $20,460 |
$5,053
143,163
kWh
|
$4,676
-
kW-mo/yr
|
$6,612
-
MMBtu
|
$1,172 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs