Assessment Year | 1998 |
---|---|
Principal Product | Slurry Pumps |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
77,000
ft2
|
Annual Production | 1,440
pieces
|
Production Hrs. Annual | 6,480
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,468 | 2,787,222 |
kWh
|
$0.030 |
Electricity Demand | $78,305 | 11,043 |
kW-mo/yr
|
$7.09 |
Electricity Fees | $10,036 | - |
|
- |
Natural Gas | $33,748 | 7,012 |
MMBtu
|
$4.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,238 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $38,962 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $22,908 | $1,500 | - | - | - | - | - | - | - | $22,908 | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $14,336 | - | - |
$14,808
-
kW-mo/yr
|
- | - | - | $(-472.0) | - | - | |
03 | 2.3132: Recharge batteries on during off-peak demand periods | $1,092 | $400 | - |
$1,092
-
kW-mo/yr
|
- | - | - | - | - | - | |
04 | 3.8142: Distill contaminated solvents for reuse | $10,231 | $11,400 | - | - | - |
$12,472
-
gal
|
$(-542.0)
-
lb
|
$(-1,119.0) | - | $(-580.0) | |
05 | 4.231: Purchase equipment instead of leasing | $3,600 | $9,500 | - | - | - | - | - | - | $3,600 | - | |
06 | 2.7261: Install timers and/or thermostats | $3,445 | $1,600 | - | - |
$3,445
-
MMBtu
|
- | - | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $626 | $640 |
$470
14,947
kWh
|
$156
-
kW-mo/yr
|
- | - | - | - | - | - | |
TOTAL RECOMMENDED | $56,238 | $25,040 |
$470
14,947
kWh
|
$16,056
-
kW-mo/yr
|
$3,445
-
MMBtu
|
$12,472
-
gal
|
$(-542.0)
-
lb
|
$(-1,591.0) | $3,600 | $22,328 | ||
TOTAL IMPLEMENTED | $38,962 | $2,540 |
$470
14,947
kWh
|
$16,056
-
kW-mo/yr
|
- | - | - | $(-472.0) | - | $22,908 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs