ITAC Assessment: WI0123
ITAC logo
ITAC Assessment: WI0123
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1991
Principal Product THREADED BELTS
NAICS
n/a
SIC 3452: Bolts, Nuts, Screws, Rivets, and Washers
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area
n/a
Annual Production 10,000
ton
Production Hrs. Annual 5,760
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $398,773 5,769,637
kWh
Natural Gas $192,977 64,022
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,415 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7494: Install storm windows and doors $11,035 $46,642 - $11,035
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $5,766 $951 $5,766
83,529
kWh
-
03 2.7447: Install vinyl strip / high speed / air curtain doors $2,946 $5,600 - $2,946
-
MMBtu
04 2.2414: Use waste heat from hot flue gases to preheat $2,556 $5,000 - $2,556
-
MMBtu
05 2.6232: Install set-back timers $1,860 - $1,860
26,964
kWh
-
06 2.3132: Recharge batteries on during off-peak demand periods $912 - $912
-
kWh
-
07 2.4221: Install compressor air intakes in coolest locations $1,455 $640 $1,455
21,102
kWh
-
08 2.2136: Install / repair insulation on steam lines $1,292 $429 - $1,292
-
MMBtu
09 2.7226: Use computer programs to optimize hvac performance $825 $700 $825
12,016
kWh
-
10 2.1233: Analyze flue gas for proper air/fuel ratio $768 $500 - $768
-
MMBtu
TOTAL RECOMMENDED $29,415 $60,462 $10,818
143,611
kWh
$18,597
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs