ITAC Assessment: WI0097
ITAC logo
ITAC Assessment: WI0097
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1990
Principal Product PLASTIC BOTTLES
NAICS
n/a
SIC 3085: Plastics Bottles
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area
n/a
Annual Production 150,000,000
pieces
Production Hrs. Annual 8,400
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,183,827 20,482,708
kWh
Natural Gas $61,595 17,359
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,264 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3132: Recharge batteries on during off-peak demand periods $15,710 $6,000 $15,710
-
kWh
-
02 2.7261: Install timers and/or thermostats $509 $1,200 - $509
-
MMBtu
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,745 $20,000 $7,745
133,939
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $121 $46 $121
2,052
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $5,833 $2,500 $5,833
100,821
kWh
-
06 2.7447: Install vinyl strip / high speed / air curtain doors $1,135 $1,200 - $1,135
-
MMBtu
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $930 $2,397 $930
16,120
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $281 - $281
4,982
kWh
-
TOTAL RECOMMENDED $32,264 $33,343 $30,620
257,914
kWh
$1,644
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs