| Assessment Year | 1990 |
|---|---|
| Principal Product | PAINTS AND VARNISHES |
| NAICS |
n/a
|
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 500
Tgal
|
| Production Hrs. Annual | 2,375
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,379 | 458,089 |
kWh
|
$0.095 |
| Natural Gas | $12,126 | 3,182 |
MMBtu
|
$3.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,504 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $687 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $3,012 | $1,250 | - |
$3,012
-
MMBtu
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $166 | $77 |
$166
1,758
kWh
|
- | |
| 03 | 2.6232: Install set-back timers | $446 | $400 |
$446
4,689
kWh
|
- | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $330 | $800 | - |
$330
-
MMBtu
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $191 | - |
$191
2,052
kWh
|
- | |
| 06 | 2.2437: Recover waste heat from equipment | $237 | $1,000 | - |
$237
-
MMBtu
|
|
| 07 | 2.7494: Install storm windows and doors | $122 | $328 | - |
$122
-
MMBtu
|
|
| TOTAL RECOMMENDED | $4,504 | $3,855 |
$803
8,499
kWh
|
$3,701
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $687 | $877 |
$357
3,810
kWh
|
$330
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs