| Assessment Year | 1990 |
|---|---|
| Principal Product | DOG BISCUITS |
| NAICS |
n/a
|
| SIC | 2047: Dog and Cat Food |
| Sales Range | $5 M to 10M |
| # of Employees | 35 |
| Plant Area |
n/a
|
| Annual Production | 8,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $63,549 | 799,824 |
kWh
|
$0.079 |
| Natural Gas | $34,118 | 12,839 |
MMBtu
|
$2.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,949 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,935 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $7,491 | $1,002 |
$(-62.0)
(-879)
kWh
|
$7,553
-
MMBtu
|
|
| 02 | 2.3132: Recharge batteries on during off-peak demand periods | $4,429 | - |
$4,429
-
kWh
|
- | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,347 | $3,300 | - |
$3,347
-
MMBtu
|
|
| 04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,973 | $5,000 |
$3,399
37,515
kWh
|
$(-426.0)
-
MMBtu
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $801 | $848 |
$801
9,965
kWh
|
- | |
| 06 | 2.7261: Install timers and/or thermostats | $1,333 | $750 | - |
$1,333
-
MMBtu
|
|
| 07 | 2.6121: Reduce hot water temperature to the minimum required | $235 | - |
$235
2,931
kWh
|
- | |
| 08 | 2.6232: Install set-back timers | $143 | $200 |
$143
1,758
kWh
|
- | |
| 09 | 2.7442: Keep doors and windows shut when not on use | $137 | - | - |
$137
-
MMBtu
|
|
| 10 | 2.7492: Use proper thickness of insulation on building envelope | $60 | $200 | - |
$60
-
MMBtu
|
|
| TOTAL RECOMMENDED | $20,949 | $11,300 |
$8,945
51,290
kWh
|
$12,004
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,935 | $1,598 |
$5,465
12,896
kWh
|
$1,470
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs