Assessment Year 1989
Principal Product ICE CREAM CONES
NAICS
n/a
SIC 2052: Cookies and Crackers
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area
n/a
Annual Production 930,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $79,229 1,247,655
kWh
Natural Gas $187,278 63,863
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $34,907 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,086

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3131: Reschedule plant operations or reduce load to avoid peaks $10,384 - $10,384
-
kWh
-
02 2.2443: Re-use or recycle hot or cold process exhaust air $8,040 $15,000 - $8,040
-
MMBtu
03 2.7261: Install timers and/or thermostats $2,768 $1,750 - $2,768
-
MMBtu
04 2.7243: Improve air circulation with destratification fans / other methods $3,284 $1,040 $(-80.0)
(-1,172)
kWh
$3,364
-
MMBtu
05 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,658 $4,000 $2,658
-
kWh
-
06 2.7226: Use computer programs to optimize hvac performance $1,822 $5,000 $1,822
28,722
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $992 $1,043 $992
15,533
kWh
-
08 2.4312: Improve lubrication practices $1,606 - $1,606
25,205
kWh
-
09 2.4221: Install compressor air intakes in coolest locations $1,100 $2,000 $1,100
17,292
kWh
-
10 2.6232: Install set-back timers $929 $400 $929
14,654
kWh
-
11 2.2437: Recover waste heat from equipment $740 $1,000 - $740
-
MMBtu
12 2.4111: Utilize energy-efficient belts and other improved mechanisms $584 $1,978 $584
9,086
kWh
-
TOTAL RECOMMENDED $34,907 $33,211 $19,995
109,320
kWh
$14,912
-
MMBtu
TOTAL IMPLEMENTED $20,086 $7,833 $13,954
14,361
kWh
$6,132
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs