| Assessment Year | 1989 |
|---|---|
| Principal Product | ICE CREAM CONES |
| NAICS |
n/a
|
| SIC | 2052: Cookies and Crackers |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 930,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $79,229 | 1,247,655 |
kWh
|
$0.064 |
| Natural Gas | $187,278 | 63,863 |
MMBtu
|
$2.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,907 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,086 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $10,384 | - |
$10,384
-
kWh
|
- | |
| 02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $8,040 | $15,000 | - |
$8,040
-
MMBtu
|
|
| 03 | 2.7261: Install timers and/or thermostats | $2,768 | $1,750 | - |
$2,768
-
MMBtu
|
|
| 04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,284 | $1,040 |
$(-80.0)
(-1,172)
kWh
|
$3,364
-
MMBtu
|
|
| 05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,658 | $4,000 |
$2,658
-
kWh
|
- | |
| 06 | 2.7226: Use computer programs to optimize hvac performance | $1,822 | $5,000 |
$1,822
28,722
kWh
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $992 | $1,043 |
$992
15,533
kWh
|
- | |
| 08 | 2.4312: Improve lubrication practices | $1,606 | - |
$1,606
25,205
kWh
|
- | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $1,100 | $2,000 |
$1,100
17,292
kWh
|
- | |
| 10 | 2.6232: Install set-back timers | $929 | $400 |
$929
14,654
kWh
|
- | |
| 11 | 2.2437: Recover waste heat from equipment | $740 | $1,000 | - |
$740
-
MMBtu
|
|
| 12 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $584 | $1,978 |
$584
9,086
kWh
|
- | |
| TOTAL RECOMMENDED | $34,907 | $33,211 |
$19,995
109,320
kWh
|
$14,912
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $20,086 | $7,833 |
$13,954
14,361
kWh
|
$6,132
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs