| Assessment Year | 1994 |
|---|---|
| Principal Product | Small Joint Prosthetics & Passive Motion Devices |
| NAICS |
n/a
|
| SIC | 2836: Biological Products, Except Diagnostic Substances |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
56,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 2,167
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $82,077 | 842,028 |
kWh
|
$0.097 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $35,315 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,280 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,108 | $100 |
$1,108
9,672
kWh
|
|
| 02 | 2.7261: Install timers and/or thermostats | $4,183 | $320 |
$4,183
51,583
kWh
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $85 | $40 |
$85
879
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,164 | $18,442 |
$7,164
59,496
kWh
|
|
| 05 | 2.7144: Install spectral reflectors / delamp | $15,519 | $13,035 |
$15,519
126,319
kWh
|
|
| 06 | 2.7132: Install timers on light switches in little used areas | $1,046 | $240 |
$1,046
10,844
kWh
|
|
| 07 | 2.3137: Use power during off-peak periods | $424 | - |
$424
-
kWh
|
|
| 08 | 2.7111: Reduce illumination to minimum necessary levels | $2,678 | $330 |
$2,678
21,395
kWh
|
|
| 09 | 2.7135: Install occupancy sensors | $1,928 | $2,800 |
$1,928
19,050
kWh
|
|
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $748 | $385 |
$748
3,224
kWh
|
|
| 11 | 2.7132: Install timers on light switches in little used areas | $432 | $125 |
$432
3,810
kWh
|
|
| TOTAL RECOMMENDED | $35,315 | $35,817 |
$35,315
306,272
kWh
|
||
| TOTAL IMPLEMENTED | $10,280 | $1,540 |
$10,280
101,407
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs