| Assessment Year | 2015 |
|---|---|
| Principal Product | Fire Turnout Gear |
| NAICS | 315220: Men’s and Boys’ Cut and Sew Apparel Manufacturing |
| SIC | 2326: Men's and Boys' Work Clothing |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
240,000
ft2
|
| Annual Production | 321,250
pieces
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $46,088 | 694,848 |
kWh
|
$0.066 |
| Electricity Demand | $18,388 | 2,438 |
kW-mo/yr
|
$7.54 |
| Electricity Fees | $7,520 | - |
|
- |
| Natural Gas | $42,072 | 2,855 |
MMBtu
|
$14.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,890 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,621 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $10,047 | $6,250 |
$8,494
128,691
kWh
|
$1,553
-
kW-mo/yr
|
- | - | |
| 02 | 2.7134: Use photocell controls | $3,354 | $750 |
$3,354
50,812
kWh
|
- | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,580 | $2,360 |
$870
13,175
kWh
|
$135
-
kW-mo/yr
|
- | $1,575 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,187 | $2,890 |
$1,667
25,247
kWh
|
$520
-
kW-mo/yr
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,527 | $2,143 |
$1,241
18,796
kWh
|
$264
-
kW-mo/yr
|
- | $22 | |
| 06 | 2.6218: Turn off equipment when not in use | $1,236 | - |
$1,236
18,720
kWh
|
- | - | - | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $849 | - |
$849
12,849
kWh
|
- | - | - | |
| 08 | 2.4152: Use only certified motor repair shops | $623 | $2,031 |
$623
9,435
kWh
|
- | - | - | |
| 09 | 2.4221: Install compressor air intakes in coolest locations | $445 | $650 |
$445
6,740
kWh
|
- | - | - | |
| 10 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $305 | $886 |
$305
4,617
kWh
|
- | - | - | |
| 11 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $427 | $273 | - | - |
$427
-
MMBtu
|
- | |
| 12 | 2.7442: Keep doors and windows shut when not on use | $310 | $90 | - | - |
$310
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $23,890 | $18,323 |
$19,084
289,082
kWh
|
$2,472
-
kW-mo/yr
|
$737
-
MMBtu
|
$1,597 | ||
| TOTAL IMPLEMENTED | $11,621 | $8,506 |
$8,368
126,750
kWh
|
$919
-
kW-mo/yr
|
$737
-
MMBtu
|
$1,597 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs