ITAC Assessment: UC2501
ITAC logo
ITAC Assessment: UC2501
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Pharmaceutical Skin care product
NAICS 325412: Pharmaceutical Preparation Manufacturing
SIC 2834: Pharmaceutical Preparations
Sales Range $100
M
to 500
M
# of Employees 200
Plant Area 54,000
ft2
Annual Production 25,000,000
units
Production Hrs. Annual 2,100
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,003 1,231,494
kWh
Electricity Demand $73,602 4,580
kW-mo/yr
Electricity Fees $11,304 -
Natural Gas $94,835 10,334
MMBtu
TOTAL YEARLY COSTS $300,743
RECOMMENDED SAVINGS* $101,477 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $8,633 - - - - $8,633 - -
02 2.7261: Install timers and/or thermostats $1,037 $3,620 $124
1,264
kWh
- $913
-
MMBtu
- - -
03 2.2511: Insulate bare equipment $4,682 $2,038 - - $4,682
-
MMBtu
- - -
04 2.9114: Use solar heat to make electricty $33,422 $218,140 $38,097
387,555
kWh
- - - $(-4,675.0) -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $16,506 $23,172 $8,131
82,720
kWh
$7,976
-
kW-mo/yr
- - $33 $366
06 2.4221: Install compressor air intakes in coolest locations $1,924 $2,400 $1,121
11,401
kWh
$803
-
kW-mo/yr
- - - -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,534 $1,600 $8,014
81,530
kWh
$2,520
-
kW-mo/yr
- - - -
08 2.6231: Utilize controls to operate equipment only when needed $2,832 $75 $2,832
28,807
kWh
- - - - -
09 2.7135: Install occupancy sensors $71 $544 $49
500
kWh
- - - $20 $1
10 2.4231: Reduce the pressure of compressed air to the minimum required $16,968 $3,500 $16,658
169,457
kWh
$311
-
kW-mo/yr
- - - -
11 2.7221: Lower temperature during the winter season and vice-versa $4,869 - $594
6,045
kWh
- $4,275
-
MMBtu
- - -
TOTAL RECOMMENDED $101,477 $255,089 $75,620
769,279
kWh
$11,609
-
kW-mo/yr
$9,870
-
MMBtu
$8,633 $(-4,622.1) $367
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs