Assessment Year | 2024 |
---|---|
Principal Product | Security hardware |
NAICS | 332510: Hardware Manufacturing |
SIC | 3429: Hardware, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 32 |
Plant Area |
43,000
ft2
|
Annual Production | 3,000,000
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,239 | 573,000 |
kWh
|
$0.15 |
Electricity Demand | $28,083 | 2,229 |
kW-mo/yr
|
$12.60 |
Electricity Fees | $5,792 | - |
|
- |
Natural Gas | $26,619 | 1,888 |
MMBtu
|
$14.10 |
TOTAL YEARLY COSTS | $144,734 | |||
RECOMMENDED SAVINGS* | $68,827 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $4,885 | - | - | - | $4,885 | - | |
02 | 2.8123: Pay utility bills on time | $64 | - | - | - | $64 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,934 | - |
$2,626
17,864
kWh
|
$308
-
kW-mo/yr
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $2,103 | $428 |
$1,882
12,801
kWh
|
$221
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,880 | $1,300 |
$5,262
35,795
kWh
|
$618
-
kW-mo/yr
|
- | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $1,576 | $50 |
$1,576
10,718
kWh
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $753 | $2,612 |
$674
4,585
kWh
|
$79
-
kW-mo/yr
|
- | - | |
08 | 2.7261: Install timers and/or thermostats | $1,116 | $333 | - | - | - |
$1,116
-
MMBtu
|
|
09 | 2.9114: Use solar heat to make electricty | $49,517 | $311,208 |
$49,517
336,847
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $68,827 | $315,931 |
$61,536
418,610
kWh
|
$1,226
-
kW-mo/yr
|
$4,949 |
$1,116
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs