Assessment Year | 2023 |
---|---|
Principal Product | Custom plastic injection molding |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
100,000
ft2
|
Annual Production | 20,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $262,183 | 2,077,208 |
kWh
|
$0.13 | |
Electricity Demand | $122,253 | 8,382 |
kW-mo/yr
|
$14.58 | |
Electricity Fees | $17,951 | - |
|
- | |
Natural Gas | $20,784 | 1,669 |
MMBtu
|
$12.45 | |
Waste Disposal Costs | |||||
Water Usage | $6,168 | 1,882 |
Tgal
|
$3.28 | |
TOTAL YEARLY COSTS | $429,338 | ||||
RECOMMENDED SAVINGS* | $17,701 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $275 | - | - | - | $275 | - | |
02 | 2.6218: Turn off equipment when not in use | $4,527 | $1,500 |
$4,527
35,873
kWh
|
- | - | - | |
03 | 2.2511: Insulate bare equipment | $1,066 | $3,500 |
$1,066
8,447
kWh
|
- | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $732 | $428 |
$632
5,005
kWh
|
$100
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $873 | $1,300 |
$754
5,973
kWh
|
$119
-
kW-mo/yr
|
- | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $251 | $50 |
$251
1,989
kWh
|
- | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,805 | $75 |
$1,559
12,351
kWh
|
$247
-
kW-mo/yr
|
- | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,884 | $16,157 |
$2,490
19,730
kWh
|
$394
-
kW-mo/yr
|
- | - | |
09 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $4,673 | $19,488 |
$2,852
22,600
kWh
|
$451
-
kW-mo/yr
|
- |
$1,370
-
MMBtu
|
|
10 | 2.7261: Install timers and/or thermostats | $615 | $1,053 |
$92
728
kWh
|
- | - |
$523
-
MMBtu
|
|
TOTAL RECOMMENDED | $17,701 | $43,550 |
$14,222
112,697
kWh
|
$1,311
-
kW-mo/yr
|
$275 |
$1,892
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs