| Assessment Year | 2002 |
|---|---|
| Principal Product | Steel industrial valves |
| NAICS |
n/a
|
| SIC | 3493: Steel Springs, Except Wire |
| Sales Range | $10 M to 50M |
| # of Employees | 107 |
| Plant Area |
93,525
ft2
|
| Annual Production | 24,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $84,004 | 2,276,084 |
kWh
|
$0.037 |
| Electricity Demand | $66,624 | 7,164 |
kW-mo/yr
|
$9.30 |
| Electricity Fees | $3,663 | - |
|
- |
| Natural Gas | $40,523 | 4,248 |
MMBtu
|
$9.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,767 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,716 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $8,051 | $5,798 | - | - | - |
$8,051
-
MMBtu
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $6,165 | $2,954 | - | - | - |
$6,165
-
MMBtu
|
- | |
| 03 | 2.7231: Use radiant heater for spot heating | $5,910 | $800 |
$2,311
67,409
kWh
|
$3,512
-
kW-mo/yr
|
$87 | - | - | |
| 04 | 2.7261: Install timers and/or thermostats | $1,270 | $100 |
$1,251
36,342
kWh
|
- | $19 | - | - | |
| 05 | 2.6214: Shut off pilots in standby equipment | $571 | $173 | - | - | - |
$571
-
MMBtu
|
- | |
| 06 | 3.5217: Reuse / recycle/ sell paper products | $4,800 | - | - | - | - | - |
$4,800
-
lb
|
|
| TOTAL RECOMMENDED | $26,767 | $9,825 |
$3,562
103,751
kWh
|
$3,512
-
kW-mo/yr
|
$106 |
$14,787
-
MMBtu
|
$4,800
-
lb
|
||
| TOTAL IMPLEMENTED | $18,716 | $4,027 |
$3,562
103,751
kWh
|
$3,512
-
kW-mo/yr
|
$106 |
$6,736
-
MMBtu
|
$4,800
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs