| Assessment Year | 1991 |
|---|---|
| Principal Product | LIGHTING ASSEMBLIES |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $5 M to 10M |
| # of Employees | 115 |
| Plant Area |
n/a
|
| Annual Production | 70,000,000
pieces
|
| Production Hrs. Annual | 4,420
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $28,501 | 337,339 |
kWh
|
$0.084 |
| LPG | $23,479 | 2,758 |
MMBtu
|
$8.51 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,234 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,234 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,139 | - |
$3,139
36,928
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,965 | - |
$2,965
34,877
kWh
|
- | |
| 03 | 2.7123: Keep lamps and reflectors clean | $3,030 | $3,024 |
$3,030
33,411
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $647 | $240 | - |
$647
-
MMBtu
|
|
| 05 | 2.2511: Insulate bare equipment | $947 | $247 |
$947
11,137
kWh
|
- | |
| 06 | 2.7123: Keep lamps and reflectors clean | $221 | $660 | - |
$221
-
MMBtu
|
|
| 07 | 2.6232: Install set-back timers | $573 | - |
$573
6,741
kWh
|
- | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $548 | $495 |
$548
6,448
kWh
|
- | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,164 | $369 |
$1,164
13,775
kWh
|
- | |
| TOTAL RECOMMENDED | $13,234 | $5,035 |
$12,366
143,317
kWh
|
$868
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,234 | $5,035 |
$12,366
143,317
kWh
|
$868
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs