Assessment Year 1991
Principal Product ELEC. ROTATING COMPONENT
NAICS
n/a
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 370
Plant Area
n/a
Annual Production 13,500
pieces
Production Hrs. Annual 4,080
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $413,263 7,372,509
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $86,742 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.7261: Install timers and/or thermostats $27,754 $8,700 $27,754
495,604
kWh
-
02 2.2511: Insulate bare equipment $23,175 $2,472 $23,175
413,834
kWh
-
03 2.7262: Separate controls of air handlers from ac/ heating systems $13,212 $7,325 $13,212
235,932
kWh
-
04 2.7221: Lower temperature during the winter season and vice-versa $8,321 - $8,321
148,593
kWh
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,938 $2,450 $2,938
52,462
kWh
-
06 2.6232: Install set-back timers $1,526 - $1,526
27,257
kWh
-
07 2.7227: Use water on air conditioning exchanger to improve heat transfer and increase air conditioner efficiency $1,477 - $1,477
26,377
kWh
-
08 2.4231: Reduce the pressure of compressed air to the minimum required $1,412 $620 $1,412
25,205
kWh
-
09 2.7111: Reduce illumination to minimum necessary levels $1,462 - $1,379
24,619
kWh
$83
10 2.7212: Install or upgrade insulation on hvac distribution systems $1,165 $799 $1,165
20,809
kWh
-
11 2.4221: Install compressor air intakes in coolest locations $1,034 $3,340 $1,034
18,464
kWh
-
12 2.7142: Utilize higher efficiency lamps and/or ballasts $2,839 $3,550 $2,839
50,703
kWh
-
13 2.7229: Air condition only space necessary $427 $675 $427
7,620
kWh
-
TOTAL RECOMMENDED $86,742 $29,931 $86,659
1,547,479
kWh
$83
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs