Assessment Year | 1991 |
---|---|
Principal Product | DIMENSIONAL HARDWARE |
NAICS |
n/a
|
SIC | 2426: Hardwood Dimension and Flooring Mills |
Sales Range | $10 M to 50M |
# of Employees | 153 |
Plant Area |
n/a
|
Annual Production | 14,700,000
lb
|
Production Hrs. Annual | 4,410
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $268,168 | 5,834,408 |
kWh
|
$0.046 |
Natural Gas | $6,667 | 1,498 |
MMBtu
|
$4.45 |
Wood | $194,000 | 252,000 |
MMBtu
|
$0.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $247,374 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Wood Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1335: Replace gasoline with diesel, lpg, or natural gas | $217,463 | - |
$222,313
4,837,632
kWh
|
- |
$(-4,850.0)
-
MMBtu
|
- | |
02 | 2.2136: Install / repair insulation on steam lines | $361 | $984 | - |
$105
-
MMBtu
|
$256
-
MMBtu
|
- | |
03 | 2.6232: Install set-back timers | $11,136 | - |
$11,136
242,087
kWh
|
- | - | - | |
04 | 2.7123: Keep lamps and reflectors clean | $8,847 | - |
$8,251
179,367
kWh
|
- | - | $596 | |
05 | 2.2122: Install / repair insulation on condensate lines | $73 | $75 | - |
$21
-
MMBtu
|
$52
-
MMBtu
|
- | |
06 | 2.7444: Close holes and openings in building such as broken windows | $2,021 | $500 | - |
$2,021
-
MMBtu
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $742 | $510 |
$742
16,120
kWh
|
- | - | - | |
08 | 2.4312: Improve lubrication practices | $634 | $2,100 |
$634
13,775
kWh
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,578 | $451 |
$1,578
34,291
kWh
|
- | - | - | |
10 | 2.4221: Install compressor air intakes in coolest locations | $607 | $660 |
$607
13,189
kWh
|
- | - | - | |
11 | 2.3212: Optimize plant power factor | $3,912 | $5,900 |
$3,912
-
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $247,374 | $11,180 |
$249,173
5,336,461
kWh
|
$2,147
-
MMBtu
|
$(-4,542.0)
-
MMBtu
|
$596 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Wood Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs