Assessment Year 1990
Principal Product HARDWOOD STRIP FLOORING
NAICS
n/a
SIC 2426: Hardwood Dimension and Flooring Mills
Sales Range $5
M
to 10
M
# of Employees 104
Plant Area
n/a
Annual Production 7,500
thousand feet
Production Hrs. Annual 2,168
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $373,454 6,600,235
kWh
Wood $112,000 137,600
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $314,706 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,154

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Wood Savings Administrative Changes Savings
01 2.3412: Use waste heat to produce steam to drive a steam turbine-generator $258,435 - $258,435
4,582,356
kWh
- -
02 2.2136: Install / repair insulation on steam lines $5,052 $9,401 - $5,052
-
MMBtu
-
03 2.2135: Repair and eliminate steam leaks $2,222 $4,000 - $2,222
-
MMBtu
-
04 2.6232: Install set-back timers $12,329 - $12,329
216,295
kWh
- -
05 2.2122: Install / repair insulation on condensate lines $524 $2,000 - $524
-
MMBtu
-
06 2.6122: Adjust vents to minimize energy use $10,842 $4,670 $10,842
190,211
kWh
- -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,374 $1,000 $10,374
182,005
kWh
- -
08 2.7123: Keep lamps and reflectors clean $6,631 $9,913 $6,251
108,441
kWh
- $380
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,692 $2,250 $3,692
64,771
kWh
- -
10 2.7261: Install timers and/or thermostats $2,859 $760 $2,859
42,204
kWh
- -
11 2.4221: Install compressor air intakes in coolest locations $952 $490 $952
16,706
kWh
- -
12 2.6211: Conserve energy by efficient use of vending machines $451 $1,740 $451
7,913
kWh
- -
13 2.7142: Utilize higher efficiency lamps and/or ballasts $343 $289 $343
5,862
kWh
- -
TOTAL RECOMMENDED $314,706 $36,513 $306,528
5,416,764
kWh
$7,798
-
MMBtu
$380
TOTAL IMPLEMENTED $45,154 $22,321 $37,356
647,421
kWh
$7,798
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Wood Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs