Assessment Year | 1989 |
---|---|
Principal Product | HAMMERS,CHISELS,PYLIERS |
NAICS |
n/a
|
SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
Sales Range | $10 M to 50M |
# of Employees | 279 |
Plant Area |
n/a
|
Annual Production | 6,700,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $780,428 | 13,597,011 |
kWh
|
$0.057 |
Natural Gas | $86,503 | 22,277 |
MMBtu
|
$3.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,303 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $59,738 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6122: Adjust vents to minimize energy use | $30,604 | $6,500 |
$30,604
536,928
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,381 | $1,110 |
$13,381
234,760
kWh
|
- | |
03 | 2.7231: Use radiant heater for spot heating | $2,488 | $5,550 | - |
$2,488
-
MMBtu
|
|
04 | 2.2191: Substitute hot process fluids for steam | $1,833 | $3,650 | - |
$1,833
-
MMBtu
|
|
05 | 2.6232: Install set-back timers | $7,384 | - |
$7,384
129,543
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $2,222 | $548 |
$2,222
38,980
kWh
|
- | |
07 | 2.7261: Install timers and/or thermostats | $2,339 | $680 |
$2,339
41,032
kWh
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,021 | - |
$2,021
35,463
kWh
|
- | |
09 | 2.7243: Improve air circulation with destratification fans / other methods | $188 | $1,750 | - |
$188
-
MMBtu
|
|
10 | 2.4221: Install compressor air intakes in coolest locations | $1,587 | $780 |
$1,587
27,843
kWh
|
- | |
11 | 2.2122: Install / repair insulation on condensate lines | $82 | $50 | - |
$82
-
MMBtu
|
|
12 | 2.2511: Insulate bare equipment | $334 | $247 |
$334
5,862
kWh
|
- | |
13 | 2.3212: Optimize plant power factor | $37,840 | $35,000 |
$37,840
-
kWh
|
- | |
TOTAL RECOMMENDED | $102,303 | $55,865 |
$97,712
1,050,411
kWh
|
$4,591
-
MMBtu
|
||
TOTAL IMPLEMENTED | $59,738 | $43,170 |
$57,168
339,098
kWh
|
$2,570
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs