| Assessment Year | 1989 |
|---|---|
| Principal Product | CERAMIC FIBERS |
| NAICS |
n/a
|
| SIC | 3299: Nonmetallic Mineral Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 143 |
| Plant Area |
n/a
|
| Annual Production | 5,000
ton
|
| Production Hrs. Annual | 8,064
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $925,747 | 19,987,105 |
kWh
|
$0.046 |
| Natural Gas | $145,399 | 31,304 |
MMBtu
|
$4.64 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,527 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,600 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $7,348 | $1,020 |
$7,348
159,730
kWh
|
- | |
| 02 | 2.4227: Use compressor air filters | $5,608 | $100 |
$5,608
121,923
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,880 | $1,000 |
$4,880
106,096
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $1,687 | $2,170 | - |
$1,687
-
MMBtu
|
|
| 05 | 2.6124: Establish equipment maintenance schedule | $1,001 | - | - |
$1,001
-
MMBtu
|
|
| 06 | 2.6232: Install set-back timers | $1,550 | - |
$1,550
33,705
kWh
|
- | |
| 07 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,240 | $6,161 |
$1,240
26,964
kWh
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $485 | $120 |
$485
10,551
kWh
|
- | |
| 09 | 2.7123: Keep lamps and reflectors clean | $418 | $1,230 |
$418
9,086
kWh
|
- | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $310 | $621 |
$310
6,741
kWh
|
- | |
| TOTAL RECOMMENDED | $24,527 | $12,422 |
$21,839
474,796
kWh
|
$2,688
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $21,600 | $4,091 |
$20,599
447,832
kWh
|
$1,001
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs