Assessment Year 2019
Principal Product Plastic containers
NAICS 326199: All Other Plastics Product Manufacturing
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $50
M
to 100
M
# of Employees 80
Plant Area 182,100
ft2
Annual Production 38,000,000
lb
Production Hrs. Annual 8,064
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,017,743 27,488,993
kWh
Electricity Demand $988,098 56,307
kW-mo/yr
Natural Gas $20,397 1,856
MMBtu
TOTAL YEARLY COSTS $3,026,239
RECOMMENDED SAVINGS* $250,335 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $76,855

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $34,284 - $23,380
318,528
kWh
$24,956
-
kW-mo/yr
$(-14,052.0)
-
MMBtu
02 2.4231: Reduce the pressure of compressed air to the minimum required $6,962 $360 $5,135
69,964
kWh
$1,827
-
kW-mo/yr
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,625 $240 $8,625
117,512
kWh
- -
04 2.2623: Minimize condenser cooling water temperature $8,499 $960 $8,499
115,786
kWh
- -
05 2.2621: Modify refrigeration system to operate at a lower pressure $40,841 $4,800 $30,123
410,401
kWh
$10,718
-
kW-mo/yr
-
06 2.6231: Utilize controls to operate equipment only when needed $6,127 $1,647 $6,127
83,467
kWh
- -
07 2.6218: Turn off equipment when not in use $4,069 $7,542 $4,069
55,441
kWh
- -
08 2.7229: Air condition only space necessary $17,743 $33,601 $17,743
241,736
kWh
- -
09 2.2511: Insulate bare equipment $3,114 $6,574 $3,114
42,422
kWh
- -
10 2.9114: Use solar heat to make electricty $120,071 $1,107,885 $99,252
1,352,208
kWh
$20,819
-
kW-mo/yr
-
TOTAL RECOMMENDED $250,335 $1,163,609 $206,067
2,807,465
kWh
$58,320
-
kW-mo/yr
$(-14,052.0)
-
MMBtu
TOTAL IMPLEMENTED $76,855 $42,422 $64,124
873,629
kWh
$26,783
-
kW-mo/yr
$(-14,052.0)
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs