Assessment Year | 1984 |
---|---|
Principal Product | POLYETHYLENE PIPE |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $1 M to 5M |
# of Employees | 36 |
Plant Area |
n/a
|
Annual Production | 3,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $90,327 | 1,550,117 |
kWh
|
$0.058 |
Natural Gas | $3,724 | 622 |
MMBtu
|
$5.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,332 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $232 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $3,128 | $340 |
$3,128
53,927
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $2,384 | $360 |
$2,006
34,584
kWh
|
$378
-
MMBtu
|
|
03 | 2.7441: Replace broken windows and/or window sash | $786 | $800 | - |
$786
-
MMBtu
|
|
04 | 2.6232: Install set-back timers | $1,802 | - |
$1,802
31,067
kWh
|
- | |
05 | 2.2511: Insulate bare equipment | $96 | $26 | - |
$96
-
MMBtu
|
|
06 | 2.6124: Establish equipment maintenance schedule | $136 | - |
$136
2,345
kWh
|
- | |
TOTAL RECOMMENDED | $8,332 | $1,526 |
$7,072
121,923
kWh
|
$1,260
-
MMBtu
|
||
TOTAL IMPLEMENTED | $232 | $26 |
$136
2,345
kWh
|
$96
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs