| Assessment Year | 1985 |
|---|---|
| Principal Product | CUSTOM GEARS |
| NAICS |
n/a
|
| SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
| Sales Range | $5 M to 10M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 750,000
lb
|
| Production Hrs. Annual | 2,450
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $72,422 | 664,713 |
kWh
|
$0.11 |
| Natural Gas | $15,114 | 2,080 |
MMBtu
|
$7.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,622 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,341 | $40 |
$1,341
12,309
kWh
|
- | |
| 02 | 2.7314: Reduce ventilation air | $935 | $1,644 | - |
$935
-
MMBtu
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $38 | $182 |
$38
293
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $2,438 | $333 |
$338
3,224
kWh
|
$2,100
-
MMBtu
|
|
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $698 | $537 | - |
$698
-
MMBtu
|
|
| 06 | 2.6214: Shut off pilots in standby equipment | $1,235 | - | - |
$1,235
-
MMBtu
|
|
| 07 | 2.6121: Reduce hot water temperature to the minimum required | $326 | - | - |
$326
-
MMBtu
|
|
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,921 | $80 | - |
$1,921
-
MMBtu
|
|
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,005 | $1,337 |
$3,005
27,550
kWh
|
- | |
| 10 | 2.5122: Replace high resistance ducts, pipes, and fittings | $166 | $80 |
$166
1,465
kWh
|
- | |
| TOTAL RECOMMENDED | $12,103 | $4,233 |
$4,888
44,841
kWh
|
$7,215
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,622 | $2,381 |
$1,507
13,774
kWh
|
$5,115
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs