| Assessment Year | 1992 |
|---|---|
| Principal Product | STEEL CASTINGS |
| NAICS |
n/a
|
| SIC | 3325: Steel Foundries, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 258 |
| Plant Area |
n/a
|
| Annual Production | 2,822
ton
|
| Production Hrs. Annual | 2,880
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $717,399 | 14,153,283 |
kWh
|
$0.051 |
| Natural Gas | $214,298 | 71,433 |
MMBtu
|
$3.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $54,448 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $34,181 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $289 | - |
$289
5,862
kWh
|
- | |
| 02 | 2.6218: Turn off equipment when not in use | $5,784 | $2,920 |
$5,784
157,093
kWh
|
- | |
| 03 | 2.3191: Use demand controller or load shedder | $524 | $750 |
$524
-
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $1,666 | $5,359 |
$1,666
35,170
kWh
|
- | |
| 05 | 2.2422: Use waste heat from hot flue gases to generate steam | $4,388 | $14,272 | - |
$4,388
-
MMBtu
|
|
| 06 | 2.4322: Use or replace with energy efficient substitutes | $26,207 | $150,000 |
$26,207
259,672
kWh
|
- | |
| 07 | 2.5194: Redesign process | $15,590 | $130,000 |
$15,590
282,239
kWh
|
- | |
| TOTAL RECOMMENDED | $54,448 | $303,301 |
$50,060
740,036
kWh
|
$4,388
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $34,181 | $159,029 |
$34,181
451,935
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs