Assessment Year | 1992 |
---|---|
Principal Product | STEEL CASTINGS |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 258 |
Plant Area |
n/a
|
Annual Production | 2,822
ton
|
Production Hrs. Annual | 2,880
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $717,399 | 14,153,283 |
kWh
|
$0.051 |
Natural Gas | $214,298 | 71,433 |
MMBtu
|
$3.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,448 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,181 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $289 | - |
$289
5,862
kWh
|
- | |
02 | 2.6218: Turn off equipment when not in use | $5,784 | $2,920 |
$5,784
157,093
kWh
|
- | |
03 | 2.3191: Use demand controller or load shedder | $524 | $750 |
$524
-
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $1,666 | $5,359 |
$1,666
35,170
kWh
|
- | |
05 | 2.2422: Use waste heat from hot flue gases to generate steam | $4,388 | $14,272 | - |
$4,388
-
MMBtu
|
|
06 | 2.4322: Use or replace with energy efficient substitutes | $26,207 | $150,000 |
$26,207
259,672
kWh
|
- | |
07 | 2.5194: Redesign process | $15,590 | $130,000 |
$15,590
282,239
kWh
|
- | |
TOTAL RECOMMENDED | $54,448 | $303,301 |
$50,060
740,036
kWh
|
$4,388
-
MMBtu
|
||
TOTAL IMPLEMENTED | $34,181 | $159,029 |
$34,181
451,935
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs