Assessment Year | 2016 |
---|---|
Principal Product | Packaging Materials |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 88 |
Plant Area |
110,000
ft2
|
Annual Production | 250,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $358,787 | 4,619,390 |
kWh
|
$0.078 |
Electricity Demand | $274,165 | 10,510 |
kW-mo/yr
|
$26.09 |
Electricity Fees | $(-30,896.0) | - |
|
- |
TOTAL YEARLY COSTS | $602,056 | |||
RECOMMENDED SAVINGS* | $108,921 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,645 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $51,914 | $30,240 |
$45,422
584,590
kWh
|
$27,864
-
kW-mo/yr
|
$(-21,372.0)
-
MMBtu
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,692 | $1,454 |
$1,152
14,827
kWh
|
$540
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,995 | $4,078 |
$3,422
44,045
kWh
|
$1,573
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $976 | $324 |
$621
7,984
kWh
|
$355
-
kW-mo/yr
|
- | |
05 | 2.4224: Upgrade controls on compressors | $13,025 | $17,000 |
$8,921
114,813
kWh
|
$4,104
-
kW-mo/yr
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,362 | $200 |
$6,362
81,877
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,385 | $2,800 |
$4,287
55,170
kWh
|
$2,098
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,632 | $12,913 |
$5,919
76,168
kWh
|
$2,713
-
kW-mo/yr
|
- | |
09 | 2.7134: Use photocell controls | $6,061 | $14,800 |
$5,796
74,597
kWh
|
$265
-
kW-mo/yr
|
- | |
10 | 2.7261: Install timers and/or thermostats | $7,037 | $270 |
$7,037
90,587
kWh
|
- | - | |
11 | 2.6231: Utilize controls to operate equipment only when needed | $1,842 | $1,098 |
$1,842
23,709
kWh
|
- | - | |
TOTAL RECOMMENDED | $108,921 | $85,177 |
$90,781
1,168,367
kWh
|
$39,512
-
kW-mo/yr
|
$(-21,372.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $50,645 | $54,737 |
$38,997
501,900
kWh
|
$11,648
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs