| Assessment Year | 1984 |
|---|---|
| Principal Product | CASUAL HOSIERY |
| NAICS |
n/a
|
| SIC | 2252: Hosiery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 26,000,000
pieces
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $117,537 | 2,356,975 |
kWh
|
$0.050 |
| Natural Gas | $163,210 | 30,590 |
MMBtu
|
$5.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $71,365 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,821 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2136: Install / repair insulation on steam lines | $31,111 | $4,573 | - |
$31,111
-
MMBtu
|
|
| 02 | 2.2441: Preheat boiler makeup water with waste process heat | $11,721 | $18,050 | - |
$11,721
-
MMBtu
|
|
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $14,298 | - |
$14,298
286,635
kWh
|
- | |
| 04 | 2.2514: Cover open tanks | $5,089 | $2,750 | - |
$5,089
-
MMBtu
|
|
| 05 | 2.2135: Repair and eliminate steam leaks | $3,742 | $140 | - |
$3,742
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $2,734 | $855 | - |
$2,734
-
MMBtu
|
|
| 07 | 2.2122: Install / repair insulation on condensate lines | $2,670 | $462 | - |
$2,670
-
MMBtu
|
|
| TOTAL RECOMMENDED | $71,365 | $26,830 |
$14,298
286,635
kWh
|
$57,067
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $51,821 | $5,175 |
$14,298
286,635
kWh
|
$37,523
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs